Linear Digital Keyless Entry System AK-3 User Manual

Page 7

Advertising
background image

5

Program all normal entry codes to use the Main Relay (Relay #1),
and only Relay #1 as the output relay. Program the code(s) that
you want to use to hold the output for an indefi nite period to the
Auxiliary Relay (Relay #2). See the following example that sets
entry codes 1234 for normal and 5678 for toggle operation.

Press:

0 1 # 1 2 3 4 # 1 2 3 4 # 1 #

01 = Programming Step; 1234 = Entry Code; 1 = Main Relay

Press:

0 1 # 5 6 7 8 # 5 6 7 8 # 2 #

01 = Programming Step; 5678 = Entry Code; 2 = Auxiliary Relay

Typical Toggle Mode Wiring
For devices triggered by a normally open circuit, wire the contacts
of the Main and Auxiliary Relays in parallel (see the Figure below).
Either relay will be able to trigger the access device. Entry codes
programmed for the Auxiliary Relay will be able to hold the output
on.

Select Door Sense or Inhibit Input

Default: Door Sense

The input (gray wire) can be programmed for DOOR SENSE or INHIBIT.

Press:

1 0 #

Input

#

Input

= 0 for Door Sense, = 1 for Inhibit

When programmed for DOOR SENSE, if an open condition on the input occurs
before access is granted (with an entry code or with the request-to-enter input) a
FORCED ENTRY output will occur. If an open condition remains 60 seconds after
a relay activation for access, a DOOR AJAR output will occur.
When programmed for INHIBIT, a closed condition on the input will prevent
Relay #1 from activating when access is requested with an entry code. This mode
is typically used with an external timer to disable the access device at certain
times.

Select Forced Entry Output

Default: Output #3

Sets which output activates if the DOOR SENSE input opens before access is
granted. This output is not timed.

Press:

1 1 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay 2 = Auxiliary Relay 3 = Output #3 4 = Output #4 0 = No Output

Select Door Ajar Output

Default: Output #4

Sets which output activates if the DOOR SENSE input stays open 60 seconds
after access is granted. This output is not timed.

Press:

1 2 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Select Keypad Lockout Output

Default: No Output

Sets which output activates when the keypad is “locked out” after too many
incorrect entry code attempts. The lockout time is 60 seconds.

Press:

1 3 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Select Keypad Active Output

Default: No Output

Sets which output activates when any keys are pressed. This output is timed. If
toggle mode is selected for the output, the timer value defaults to 2 seconds.

Press:

1 4 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Select Alarm Shunt Output

Default: No Output

Sets which output activates during the time access is granted. (Use this output
to shunt alarm contacts attached to the access door.) This output may be timed
or toggled.

Press:

1 5 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Select Request-to-Exit Output

Default: Main Relay

Sets which output activates when the Request-to-Exit input is grounded. This
output may be timed or toggled.

Press:

1 6 #

Output

#

Output

= Output to Activate (0-4)

1 = Main Relay, 2 = Auxiliary Relay, 3 = Output #3, 4 = Output #4, 0 = No Output

Main Relay On-time

Default: 2 Seconds

Sets the length of time the Main Relay activates when triggered.

Press:

2 1 #

Seconds

#

Seconds

= Output time in seconds (0-60), 99 = Toggle Mode

Auxiliary Relay On-time

Default: 2 Seconds

Sets the length of time Auxiliary Relay activates when triggered.

Press:

2 2 #

Seconds

#

Seconds

= Output time in seconds (0-60), 99 = Toggle Mode

Solid-state Output #3 On-time

Default: 2 Seconds

Sets the length of time Output #3 activates when triggered.

Press:

2 3 #

Seconds

#

Seconds

= Output time in seconds (0-60), 99 = Toggle Mode

Solid-state Output #4 On-time

Default: 2 Seconds

Sets the length of time Output #4 activates when triggered.

Press:

2 4 #

Seconds

#

Seconds

= Output time in seconds (0-60), 99 = Toggle Mode

Beep Sounds on Keystrokes

Default: Yes

Selects whether or not the keypad beeps as each key is pressed.

Press:

4 0 #

Sound

#

Sound

= 1 for Yes, = 0 for No

Beep Sounds During Main Relay

Default: No

Selects whether or not the keypad beeps during Main Relay activation.

Press:

4 1 #

Sound

#

Sound

= 1 for Yes, = 0 for No

221025 B IMAGE 7

N.O.

COMMON

N.C.

N.O.

COMMON

N.C.

MAIN

RELAY

AUXILIARY

RELAY

AK-3

OUTPUTS

ACCESS

DEVICE

EITHER RELAY CAN TRIGGER
THE ACCESS DEVICE