Lincoln Electric MC-439 User Manual

For welding consumables and related products, Us-cw353, Outershield mc-439

Advertising
background image

Date:

11/1/06

MSDS No.:

US-CW353

Trade Name:

Outershield MC-439

Sizes: All

Supersedes:

7/1/99

M A T E R I A L S A F E T Y D A T A S H E E T

For Welding Consumables and Related Products

Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988

SECTION I - IDENTIFICATION

Product Type:

Cored Electrode

Manufacturer/
Supplier:


The Lincoln Electric Company
22801 St. Clair Avenue
Cleveland, OH 44117-1199
(216) 481-8100

Classification:

None

SECTION II - HAZARDOUS MATERIAL (1)

I M P O R T A N T !

This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal

use of this product are covered by Section V; see it for industrial hygiene information.

CAS Number shown is representative for the ingredients listed. All ingredients listed may not be present in all sizes.

(1) The term “hazardous” in “Hazardous Materials” should be interpreted as a term required and defined in the Hazards Communication

Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory.

Ingredients:

CAS No.

Wt.%

TLV

mg/m

3

PEL

mg/m

3

Chromium and chromium alloys or compounds (as Cr)***

7440-47-3

20

0.5(b)

1.0(b)

Titanium and/or titanium alloys (as Ti)

12719-90-3

< 5

10*

10*

Manganese and/or manganese alloys and compounds (as Mn)***

7439-96-5

0.5

0.2

1.0(c)

Silicon and/or silicon alloys and compounds (as Si)

7440-21-3

0.5

10*

10*

Iron

7439-89-6

< 0.5

10*

10*

Aluminum and/or aluminum alloys (as Al)***

7429-90-5

< 0.5

10

15

Carbon steel tube

7439-89-6 80

10*

10*

Supplemental Information:

(*) Not listed. Nuisance value maximum

is 10 milligrams per cubic meter. PEL value for iron oxide is 10 mg/m

3

. TLV

value for iron oxide is 5 milligrams per cubic meter.

(***) Subject to the reporting requirements of Sections 311, 312, and 313 of the

Emergency Planning and Community Right-to-Know Act of 1986 and of
40CFR 370 and 372.



(b) The OSHA PEL for chromium (VI) is 5 micrograms
(0.005 milligrams) per cubic meter. The TLV for water
soluble chromium (VI) is 0.05 milligrams per cubic meter
and the TLV for insoluble chromium (VI) is 0.01
milligrams per cubic meter.

(c) Values are for manganese fume. STEL (Short Term
Exposure Limit) is 3.0 milligrams per cubic meter.
Values are those proposed by OSHA in 1989. Present
PEL is 5.0 milligrams per cubic meter (ceiling value).

SECTION III - HAZARD DATA

Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI. Product is inert, no

special handling or spill procedures required. Not regulated by DOT.