A) If using a Leviton Z-Wave

TM

Programmer/Remote, Cat. No. RZCPG,

press the Menu button and scroll down to System Setup. Press the

center button to select System Setup Menu. Press the center button

to select Network. Scroll down to <Exclude Node> and press the

center button.

B) If using RZCPG Programmer/Remote, you will be prompted to place

4-Zone controller into programming mode.

C) To access Program mode, press and hold the left side of buttons 1

and 3 (refer to figure). Wait 5 seconds until the LED turns Amber.

Release the buttons and the LED will blink Amber. You are now in

Programming mode.

NOTE: If the LED on the 4-Zone controller turns solid Red while

excluding, there has been a communication error.

D) While standing close to the 4-Zone controller (approximately 2-5 ft.),

press the center button on the Programmer/Remote to <Exclude>

device in the network.

Factory Default:

If your 4-Zone controller is not responding, or you are unable to control

it after you have tried to Include/Exclude it multiple times, it may be

necessary to reset the 4-Zone controller to its original factory settings. To

accomplish this, proceed as follows:
• On the 4-Zone controller (refer to figure), press

and hold the left side of buttons 1 and 3. Wait

approximately 5 seconds until the locator LED

turns Amber and then turns solid Red. Release

the buttons. The 4-Zone controller is now reset.

Once the controller is reset, it will be necessary to

Re-Include it to a network before it can be used.

CAUTION:

SETTING A DEVICE TO A FACTORY

DEFAULT DOES NOT EXCLUDE THAT DEVICE

FROM A NETWORK. THE EXCLUSION

PROCEDURE MUST STILL BE FOLLOWED TO

REMOVE THE DEVICE FROM THE PRIMARY

CONTROLLER’S INFORMATION TABLE. FAILURE

TO DO SO MAY RESULT IN SYSTEM THAT IS SLOW TO RESPOND,

OR MAY FAIL TO RESPOND TO SOME DEVICES.

DI-000-RZCZ4-00A-X1

lIMITED 5 YEAR WARRANTY AND EXClUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship under normal and proper use for five years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement,

at its option, if within such five year period the product is returned prepaid, with proof of purchase date, and a description of the problem to leviton Manufacturing Co., Inc., Att: Quality Assurance Department, 59-25 little Neck Parkway, little Neck, New York 11362-2591. This warranty excludes and there is disclaimed liability

for labor for removal of this product or reinstallation. This warranty is void if this product is installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance with any labels or instructions. There are no other or

implied warranties of any kind, including merchantability and fitness for a particular purpose, but if any implied warranty is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to five years. leviton is not liable for incidental,

indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or delay or failure to perform this warranty obligation. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

Restore Power:

Restore power at circuit breaker or fuse.

Installation is complete.

Step 10

Step 6 cont'd

Programmer/Remote

Cat. No. RZCPG

NOTE: Programmer/Remote must be

in close proximity to 4-Zone controller

when including in the network.

Step 7

Excluding 4-Zone Controller from

Z-Wave

TM

Network:

For additional information, contact leviton’s

Techline at 1-800-824-3005 or visit leviton’s

website at www.ViziaRF.com

U.S. & Foreign Patents Pending

Copyright© 2006 Leviton Manufacturing Co., Inc.

All Rights Including Trade Dress Rights Reserved

This equipment has been tested and found to comply with the limits for a

Class B Digital Device, pursuant to Part 15 of the FCC Rules. These limits

are designed to provide reasonable protection against harmful interference

in a residential installation. This equipment generates, uses, and can radiate

radio frequency energy and, if not installed and used in accordance with

the instructions, may cause harmful interference to radio communications.

However, there is no guarantee that interference will not occur in a particular

installation. If this equipment does cause harmful interference to radio or

television reception, which can be determined by turning the equipment

OFF and ON, the user is encouraged to try to correct the interference by

one or more of the following measures:
• Reorient or relocate the receiving Antenna.
• Increase the separation between the equipment and the receiver.
• Connect the equipment into an outlet on a circuit different from that to

which the receiver is connected.

• Consult the dealer or an experienced radio/tv technician for help.

FCC COMPlIANCE

STATEMENT

TROUBlESHOOTING

Including 4-Zone Controller into

Z-Wave

TM

Network:

After inclusion process, you must associate the devices to

the controllers. Refer to the Primary Programmer/Remote

instruction sheet for complete details.

NOTE: One (1) Z-Wave

TM

device can be associated to multiple controllers

(up to five (5) controllers maximum).
NOTE: If using a non-Leviton Programmer/Remote, refer to the

Programmer/Remote instruction sheet for associating a device.

Step 8

Device Association:

Step 9

4-Zone Controller Mounting:

TURN OFF POWER AT CIRCUIT BREAKER OR FUSE.

Installation may now be completed by

tightening mounting screws into wall box.

Attach wallplate.

NOTES

• locator lED on controller does not turn ON
- Circuit breaker or fuse has tripped.

- If 4-Zone controller is powered up and LED does not turn ON, check

wiring.

• Zone Controller does not operate lights
- Check association.

- Ensure that controller was properly updated.

If lED turns solid red

- Check association.

- Ensure that each device in the network is with in 70 ft (21 m) of another

device.

locator

lED

Push

Buttons

Push Button (Default settings)
Turn ON from OFF position:

Press left side of button – Turns all lights in

Zone/Area ON, LED turns ON.

LED will blink until Zone/Area is ON.
Turn OFF from ON position:

Press right side of button – Turns all lights in

Zone/Area OFF, LED turns OFF.
Dim/Bright:
Press left side of Dim/Bright button - Lights in

last activated Zone/Area will dim.
Press right side of Dim/Bright button - Lights in

last activated Zone/Area will brighten.
NOTE: Controller will only Dim/Bright devices

located within the Radio Frequency range.
NOTE: LED will be lit Green if any one load in

the associated Area is ON. LED will be OFF

when all loads are turned OFF.
If there is a power outage, when the power is

restored, the lights will return to the last setting

before the power interruption.