A-7

INSTALLATION

LN-25™ PRO

A-7

ACROSS THE ARC SET-UPS

CC Power Sources with Output Terminals Always
Hot (See Figure A.5)

If the power source has a Remote/Local switch, place
the switch in the Local position.

Place the CV/CC switch in the feeder in the "CC" posi-
tion.

CV

Power Sources with Stud Connectors and

Remote/Local Switch (See Figure A.6)

Place the power source Remote/Local switch in the
Local position.

Place CV/CC switch in the feeder in the "CV" position.

Work clip

Work

Electrode

LN-25™ PRO

CC Power Source

Classics

Big Red’s

Eagle 10,000 Plus

Pipeliner 200D Without Wire Feed module

SAE’s Without CV Adapter

SAE 400 with CV adapter

Engine Driven welder with

Wire Feed Module

Work clip

Work

Electrode

LN-25™ PRO

CC Power Source

Classics

Big Red’s

Eagle 10,000 Plus

Pipeliner 200D Without Wire Feed module

SAE’s Without CV Adapter

SAE 400 with CV adapter

Engine Driven welder with

Wire Feed Module

Work clip

Work

Electrode

LN-25™ PRO

CV-655

DC-400

DC-600

DC-655

V450-Pro

SAE 400 with CV adapter

Engine Driven welder with

Wire Feed Module

Ranger 250 GXT

Work clip

Work

Electrode

LN-25™ PRO

CV-655

DC-400

DC-600

DC-655

V450-Pro

SAE 400 with CV adapter

Engine Driven welder with

Wire Feed Module

Ranger 250 GXT

FIGURE A.5

FIGURE A.6

K#

K2613-1
K2613-2

KP1695-XX
KP1696-XX
KP1697-XX

See Magnum Literature

K1803-1

Description

LN-25™ PRO

LN-25™ PRO Extra Torque

Drive Roll Kit

Welding Gun

CC power Source

Welding Cables

POWER SOURCE TO LN-25™ PRO
CAbLE CONNECTION DIAGRAMS

K#

K2613-1
K2613-2

KP1695-XX
KP1696-XX
KP1697-XX

See magnum Literature

K1803-1

Description

LN-25™ PRO

LN-25™ PRO Extra Torque

Drive Roll Kit

Welding Gun

CV power Source

Welding Cables