4f42, Architectural decorative, Features – Lightolier Architectural Decorative 4F42 User Manual

Page 2: Lamping (by others), Electrical, Mounting, Labels, Application data, Job information type

Advertising
background image

0-30

696

2.72

3.37

0-40

1147

4.48

5.56

0-60

2066

8.07

10.01

0-90

2898

11.32

14.04

40-90

1750

6.84

8.48

60-90

831

3.25

4.03

90-180

17747

69.33

85.96

0-180

20646

80.65

100.00

** EFFICIENCY = 80.6% **

ZONAL LUMENS AND PERCENTAGES

CERTIFIED TEST REPORT NO. 4A42842A

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4A42842A, HOUSING COVER WITHOUT FLANGE, 42” DIFFUSER

8-42W PLT TRIPLE TUBE PHILIPS LAMPS. LUMEN RATING = 3200 LMS.

4-OSRAM BALLASTS, #M2-CF-26/32/42-B-M-UNIV., 120 VAC

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

C

ANDLEPOWER SUMMARY

DATE: SEPT. 15, 2000
PREPARED FOR:
LIGHTOLIER, FALL RIVER, MA

0

890

90

136

5

884

84

95

347

532

10

874

100

1122

15

856

242

105

1847

1900

20

831

110

2367

25

800

370

115

2832

2796

30

763

120

3237

35

721

452

125

3618

3234

40

672

130

3949

45

617

477

135

4137

3187

50

556

140

4240

55

493

442

145

4346

2737

60

429

150

4495

65

371

369

155

4491

2016

70

314

160

3947

75

261

277

165

3412

998

80

212

170

3313

85

166

186

175

3685

347

90

136

180

3859

ANGLE MEAN CP LUMENS ANGLE MEAN CP LUMENS

ROOM

CA

VITY

RA

TIO

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80

70

50

30

10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1

.69 .66 .63

.60 .58 .55 .44 .43 .41 .30 .29 .28 .16 .16 .15 .08

2

.60 .55 .51

.52 .49 .45 .39 .36 .34 .26 .24 .23 .14 .13 .13 .07

3

.53 .47 .43

.46 .42 .38 .34 .31 .29 .23 .21 .20 .12 .12 .11 .06

4

.46 .40 .36

.41 .36 .32 .30 .27 .24 .20 .18 .17 .11 .10 .09 .05

5

.40 .35 .30

.36 .31 .27 .27 .23 .21 .18 .16 .14 .10 .09 .08 .04

6

.37 .30 .26

.32 .27 .23 .24 .20 .18 .16 .14 .12 .09 .08 .07 .04

7

.33 .27 .22

.29 .24 .20 .21 .18 .15 .15 .12 .11 .08 .07 .06 .03

8

.39 .29 .24

.26 .21 .17 .19 .16 .13 .13 .11 .09 .07 .06 .06 .03

9

.36 .27 .21

.23 .19 .15 .18 .14 .12 .12 .10 .08 .07 .05 .05 .02

10

.33 .24 .19

.21 .17 .13 .16 .13 .10 .11 .09 .07 .06 .05 .04 .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

Features

1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia.

fastened internally, no exposed hardware. Permits installation on ceilings
with slope of up to 45°. Complies with California Code.

5. Multiple Stems: 3/8” Steel outer pipe stems surround center stem and go

into collector plate.

6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or

GX24q-4 lamp base.

7. Flange Trim: Steel 20 gauge, Plated or Painted Finish.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

General Electric

Osram/Sylvania

Philips

26W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F26TBX/*/A/4P

CF26DT/E/IN/*

PL-T26W/*/4P

32W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F32TBX/*/A/4P

CF32DT/E/IN/*

PL-T32W/*/4P

42W Triple Tube 4-Pin (Amalgam) Compact Fluorescent Lamp

F42QBK/*/A/4P

CF42DT/E/IN/*

PL-T42W/*/4P

*Manufacturers’ color temperature designation.

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start.
Universal Voltage 120/277V, Multi-Wattage 26/32/42W.

8 Lamps

26 Watt

32Watt

42Watt

Voltage

120V

277V

120V

277V

120V 277V

Total Input Watts

224

224

276

276

364

364

Max. Line Current (amps) 1.84

0.8

2.32

1.04

3.04

1.28

Power Factor

>.98

>.98

>.98

>.98

>.98

>.99

Ballast Factor

1.02

1.02

1.00

1.00

0.98

0.98

THD<10% Minimum Starting Temperature 0°F /-18°C.

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus listed suitable for damp locations.

Application Data

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.

42 Inch Diameter
45’ x 45’ x 12’ Space
Luminaire

Spacing: 15’ x 15’
Susp. Dist. 42”

8 Lamps

26W

32W

42W

TTT

TTT

TTT

Illum. (FC)

29

39

52

Maint.
Lum.

10/1

10/1

11/1

Ratio
Watts/

0.98

1.21

1.65

Sq. Ft.

Architectural Decorative

4F42

Page 2 of 2

Pendalux Gemini 42” Diameter Body 8-26/32/42 Triple Tube

Lightolier

a Genlyte company

www.lightolier.com

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2005 Genlyte Group LLC • C0605

Job Information

Type:

Advertising