EXTERNAL CONTROL DEVICE SETUP

31. Temperature value (Command: d n)

To read the inside temperature value.

Transmission
[d][n][ ][Set ID][ ][Data][x]

* The data is always FF(in Hex).

Acknowledgement
[n][ ][Set ID][ ][OK/NG][Data][x]

* The data is 1 byte long in Hexadecimal.

32. Lamp fault Check (Command: d p)

To check lamp fault.

Transmission
[d][p][ ][Set ID][ ][Data][x]

* The data is always FF(in Hex).

Acknowledgement
[p][ ][Set ID][ ][OK/NG][Data][x]

* The data is 1 byte long in Hexadecimal.

Data 00 : Lamp Fault

01 : Lamp Ok

02 : N/A (DPM/Power Off)

33. Auto volume (Command: d u)

Automatically adjust the volume level.

Transmission
[d][u][ ][Set ID][ ][Data][x]

Data 00: Off

Data 01: On

Acknowledgement
[u][ ][Set ID][ ][OK/NG][Data][x]

34. Speaker (Command: d v)

Turn the speaker on or off.

Transmission
[d][v][ ][Set ID][ ][Data][x]

Data 00: Off

Data 01: On

Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][x

35. Time (Command: f a)

Set the current time.

Transmission
[f][a][ ][Set ID][ ][Data1][ ][Data2][ ][Data3][Cr]

[Data1]

00 : Monday

01 : Tuesday

02 : Wednesday

03 : Thursday

04 : Friday

05 : Saturday

06 : Sunday

[Data2]

0H to 17H (Hours)

[Data3]

00H to 3BH (Minutes)

Acknowledgement
[a][ ][Set ID][ ][OK/NG][Data1][Data2][Data3][x]

*When reading data, FFH is inputted for [Data1],

[Data2] and [Data3]. In other cases, all are treated as

NG.