9. TRANSFORMER REPLACEMENT (Fig. K)

1. Make sure power is off.
2. Remove REFLECTOR TRIM from ceiling.
3. Remove SCREW and lift TRANSFORMER off bracket.
4. Remove J-BOX COVER by removing wing nut.
5. Unsplice primary leads in J-BOX.
6. Remove primary leads from J-BOX cover and clip attached to side

of housing.

7. Cut secondary (red) leads 6" to 8" from TRANSFORMER and dis-

card faulty transformer.

8. Install new TRANSFORMER:

(WARNING: RISK OF FIRE. Transformer contains fixture thermal
protector. Replace as shown and described below. Use only
replacement transformer obtained from LIGHTOLIER.)

a. Splice secondary (red) leads to socket leads.
b. Attach TRANSFORMER to BRACKET with SCREW, making

sure that the side of transformer that has the wire leads is
facing the housing wall (Fig.L)

c. Put primary leads through clip and bushing in the J-BOX

COVER.

e. Wire primary leads to supply leads.
f. Replace J-BOX COVER.
g. Install REFLECTOR TRIM.

Fig. K

ROTO CLIPS

JUNCTION BOX
MAX. OF (6) #12 AWG BRANCH
CIRCUIT CONDUCTORS SUITABLE
FOR AT LEAST 90° C PERMITTED
IN JUNCTION BOX.

TRANSFORMER
PRIMARY: 120V, 60HZ
SECONDARY: 110V, 50W LOAD

SCREW

SECONDARY
(RED) LEADS

PRIMARY
LEADS

CLIP

INSTRUCTION SHEET NO.

IS:1004ICV

B1204 Page 4 of 4

READ AND UNDERSTAND THESE INSTRUCTIONS BEFORE INSTALLING FIXTURE

This fixture is intended for installation in accordance with the National Electrical Code and local regulations.
To assure full compliance with local codes and regulations, check with your local electrical inspector before
installation. To prevent electrical shock, turn off electricity at fuse box before proceeding.

Retain these instructions for maintenance reference.

®

LIGHTOLIER a GENLYTE company.
631 Airport Road, Fall River, MA 02720

APERTURE
HOLE

TRANSFORMER

WIRE LEADS

HOUSING
WALL

Fig. L

Advertising