Lowrance electronic LRA-2400 User Manual

Page 15

Advertising
background image

9

2. Press

→|↓ to

A

DJUST

T

RIGGER

D

ELAY

and press

ENT

. That will launch

the Adjust Trigger Delay vertical scrollbar.
3. Press

↓ until Trigger Delay is set to zero percent. Press

EXIT

.

Adjust Trigger Delay
This feature eliminates the time lag between real radar returns and the
time it takes data to be processed by the radar software, a common is-

sue with all radars.
Caution:

If you have any doubt about your understanding of the Trigger
Delay feature, you should have it set up by a qualified radar

technician.

1. The radar should already be in STANDBY mode, so press

PWR

for 2

seconds to switch the radar into transmission mode. A confirmation
message will appear, press

← to select

Y

ES

.

2. Press

MENU

, select

G

AIN

and press

ENT

. Press

↑ to increase the Gain

level to around 15%. One or two red rings with blue borders should be

visible on the screen, depending on the wattage of your radar antenna.

3. Press

→|↓ to

A

DJUST

T

RIGGER

D

ELAY

, then press

ENT

.

The 2 kW model, the LRA-1800, will have only one ring on the display.

The 4 kW model, the LRA-2400, will have two rings on the display. See
the following figures.

Before adjusting the Trigger Delay for 4 kW radars, two rings will be

shown on the screen (left). As Trigger Delay is increased, the larger

ring will start to get smaller. The small ring will disappear (right).

You may have to increase gain in the previous step if the rings are not

visible. Increase gain until you have solid red rings shown on the
screen, like in the preceding example. Increasing Gain too much can

cause the rings to be distorted.