Table 8-2 cpm cps status fields and descriptions – Lantronix XPort AR User Manual

Page 62

Advertising
background image

8: Configurable Pins Manager

XPort AR User Guide

62

2.

Click a CP number (CP column) to display the status of that pin. The status is shown in the CP
Status section of the web page.

Table 8-2

lists and describes the fields for the selected CP.

Note:

To modify a CP, all groups in which it is a member must be disabled. The changes

to a CP are not saved in FLASH.

Value

Shows the current value of the CP.

Groups

Indicates the number of groups in which the CP is a member.

Active In Group

Shows the group in which the CP is active. A CP can be a member of several
groups. However, it may only be active in one group.

Table 8-2

CPM CPs Status Fields and Descriptions

Fields

Description

Name

Shows the CP number.

State

Shows the current enable state of the CP. On the XPort AR the CP state is
always enabled.

Type

Indicates whether the CP is set for input or output.

Value

Shows the current value of the CP.

Bit

Shows the bit position. CPs are always displayed in bit position zero.

Level

Indicates the voltage level of the CP. A plus sign (+) indicates the CP is
asserted (the voltage is high). A minus sign (-) indicates the CP voltage is
low.

I/O

Indicates the current status of the pin:

I—Input

O—Output

<blank—Unassigned

Logic

Indicates that the CP is inverted by displaying an "I".

Binary

Shows the assertion value of the corresponding bit.

CP#

Shows the CP number.

Groups

Lists the groups in which the CP is a member.

Table 8-1

CPM CPs Current Configuration Fields and Descriptions (continued)

Field

Description