For altitudes above 2,000 feet (In Canada 4,500 FT/1370 M), the orifice

should be de­rated by 4% for every 1,000 feet to maintain the proper

ratio of gas to air. Improper orifice sizing may result in damage and

unsafe conditions. Changing the orifice should only be done by a quali­

fied service technician. Contact your Lennox Hearth Products dealer for

proper orifice sizes.

ORIFICE SIZE/ALTITUDE ADJUSTMENT

Fireplace Requirements

These heaters are designed to be installed into an existing masonry

fireplace (built to UBC 37 or ULC S628 standards) or factory built solid

fuel, wood burning fireplace (listed to UL 127 or ULC S610) only. All

exhaust gases must be vented outside the structure. Combustion air

is drawn from outside the structure. When installing in a factory built

fireplace, the fireplace grate must be removed and the damper must be

removed or secured open.

If the factory­built fireplace has no gas access hole(s) provided, an access

hole of 1­1/2 inches (38 mm) or less may be drilled through the lower

sides or bottom of the firebox in a proper workmanship like manner. This

access hole must be plugged with a non­combustible insulation after the

gas supply line has been installed. The installer must mechanically attach

the marking supplied with the gas fireplace insert to the inside of the firebox

of the fireplace into which the gas fireplace insert is installed.

Si le foyer préfabriqué ne comporte pas d’orifices d’amenée du gaz, un

orifice d’au plus 37,5 mm (1,5 po) peut être pratiqué, selon les règles

de l’art, dans la partie inférieure des parois ou au fond de la chambre de

combustion. Cet orifice doit être obturé au moyen d’isolant incombustible

une fois la conduite de gaz en place.

IMPORTANT: When installing these appliances into a factory

built fireplace or heat-form, the air flow within and around the

fireplace shall not be altered by the installation of the insert

(i.e. DO NOT BLOCK louvers or cooling air inlet or outlet ports,

circulating air chambers in a steel fireplace liner or metal heat

circulator).

See Page 9 for instructions on affixing fireplace warning label

shown below.

THE FIREPLACE INSERT

Since there are always several potential sources of fire in any home, we

recommend installing smoke detectors. If possible, install the smoke

detector in a hallway adjacent to the room (to reduce the possibility of

occasional false activation from the heat produced by the appliance). If

your local code requires a smoke detector be installed within the same

room, you must follow the requirements of your local code. Check with

your local building department for requirements in your area.

SMOKE DETECTORS

WARNING

THIS FIREPLACE HAS BEEN ALTERED TO

ACCOMMODATE A FIREPLACE INSERT AND

SHOULD BE INSPECTED BY A QUALIFIED

PERSON PRIOR TO RE-USE AS A

CONVENTIONAL FIREPLACE.

• Must conform with all local, state and national installation codes. In

the absence of local codes, the installation must conform with National

Fuel Gas Code ANSI Z223.1 ­ latest edition, also known as NFPA 54

(In Canada, the current CAN/CSA B149.1 installation code). Refer to

the National Fuel Gas Code and local zoning and code authorities for

details on installation requirements.

• Mobile home installations must conform with the Mobile Home Con­

struction and Safety Standard, Title 24 CFR, Part 3280 (in Canada

CAN/CSA Z240 MH), or, when such a standard is not applicable, the

Standard for Mobile Home Installations, ANSI A225.1 ­ latest edi­

tion.

• Must be vented directly to the outside in accordance with the latest

edition of the National Fuel Gas Code and must never be attached to

a chimney serving a separate solid fuel burning appliance.

• Has been certified for use with either natural gas or propane.

• Is NOT for use with solid fuels.

• Is approved for sitting rooms and/or bedrooms.

• This appliance is suitable for installation into masonry or factory built

fireplaces.

Advertising