Pbus accessories, Wiegand accessories – Linear AE-1000 User Manual

Page 14

Advertising
background image

14

220777 C IMAGE 14

PBUS Accessories

Several accessories (keypads, proximity readers, remote receivers) can
be connected to the AE-1000’s three PBUS input/output ports. A typical
application for a remote keypad would be to control a second door or
gate.
Linear’s PBUS devices compatible with the AE-1000 are:

• AM-RRR Remote Radio Receiver
• AM-RPR Radio Proximity Receiver
• AM-KP Exterior Keypad
• AM-KPI Interior Keypad
• AM-CRI Card Reader Interface

1. Mount and install the accessory as described in its installation

instructions.

2. Route 6-conductor cable from the AE-1000 to the accessory.

For wire runs up to 300 feet use 24 AWG Belden Type 9931 or
equivalent.

For wire runs up to 600 feet use 20 AWG Weico Type 9405 or
equivalent.

3. Set

the

DEVICE ADDRESS rotary switch in the accessory to

a unique address number. When programming the system, the
device address number will identify each PBUS accessory to the
AE-1000.

4. Connect the 6-conductor cable to the accessory and the AE-1000.

Wiegand Accessories

The two AE-1000 Wiegand inputs (WIEGAND A & B) can connect to
a large variety of 26, 30, and 31-bit Wiegand output accessories. The
Wiegand format is a common standard for access control equipment.
A typical application would be to add swipe card or proximity readers to
the system.

NOTE: Depending on the Wiegand accessory used, the LED1,

LED2, and HOLD connections may not be required.

• LED1 output is switched to ground during non-access time.
• LED2 output is switched to ground for one second during access

time.

1. Mount and install the Wiegand accessory as described in its

installation instructions.

2. Route a cable from the AE-1000 to the accessory.
• For wire runs up to 300 feet use 24 AWG Belden Type 9931 or

equivalent.

• For wire runs up to 500 feet use 20 AWG Weico Type 9405 or

equivalent.

3. Connect the cable to the accessory and the AE-1000 as shown in

the fi gure.

REMOTE

PBUS

DEVICE

PCLK

DVAL

DAT0

DAT1

GND

PWR

GND
DAT1
DAT0
DVAL
PCLK

PWR

PBUS

TERMINALS

SET THE REMOTE
DEVICE ADDRESS
SWITCH TO A UNIQUE
DEVICE ADDRESS

NOTE: UP TO SIX PBUS
DEVICES MAY BE CONNECTED
TO THE THREE SETS OF AM-1000
PBUS TERMINALS

REMOTE

WIEGAND

DEVICE

LED2

HOLD

LED1

DAT1
DAT0

GND

DAT0

DAT1

LED1

HOLD

LED2

GND

WIEGAND

TERMINALS

PWR

PWR

NOTE: THE LED1, LED2, AND HOLD
CONNECTIONS MAY NOT BE REQUIRED
DEPENDING ON THE WIEGAND DEVICE USED

Advertising