Thomas & Betts wire terminals (or equal) recommended above are required to comply with applicable U.L. standards for safety. A #30 hex

(Allen) key wrench is required for assembly of terminals to wire. Based on National Electrical Code - 100% Duty Cycle 40˚C (104˚F)
Ambient.

Weight

1649lbs.

748(kg.)

INPUT - SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT (SMAW)

PHYSICAL DIMENSIONS

RECOMMENDED INPUT WIRE GROUNDING CONDUCTOR AND FUSE SIzES*

Standard Voltage

Duty Cycle

100%

Current Range

240/1500

Volts

Amps

Maximum Open

Circuit Voltage

“MIN” Terminal

30-44

240-600

“MED” Terminal

38-44

460-1060

“MAX” Terminal

44

890-1500

Depth

38.00in.

(965.2mm.)

Width

22.30 in.

(566.4mm.)

Height

53.50 in.

( 1358.9mm.)

AMPS AC

1500 @ 44 Volts

Input Current at 100% Rated Output

Single Phase Output

Scott Connection

380/50/60

Rated Input Current With P.F. Capacitors

310 Amp Single Phase

358 Amp Scott-connection

310

358

TECHNICAL SPECIFICATIONS - IDEALARC™ AC-1500

86

RATING: IP21 ENCLOSURE, INSULATION 155°(F)

Idle Current With P.F. Capacitors

70

Power Factor @ Rated load With P.F. Capacitors

71%

Power Input Wires

Grounding Conductor

Input Amps

Copper Wire Size – 75˚C in Conduit

Super Lag Fuses

Size in Amps

Input

Volts/

Hz.

380/50

310

358 500MCM 31013 600MCM 31015 #3 31007 #2 31007 400

500

(250mm

2

)

(300mm

2

)

(25mm

2

)

(35mm

2

)

1

Scott 1 T&b Scott T&b 1 T&b Scott T&b 1 Scott

Phase

Conn. Phase Term. Conn. Term. Phase Term. Conn. Term. Phase Conn.

Advertising