Liebert Y User Manual

Liebert Computer Accessories

Advertising
background image

Liebert Corporation • 1050 Dearborn Drive • PO Box 29186 • Columbus, OH 43229
Phone 607-724-2484 • Fax 607-722-8713 • US & Canada 800-288-6169
EMAIL: [email protected] • Web Site: www.Liebert.com

82247 Rev 0

Liebert AC Power Low Exposure Transient Voltage Surge Suppressor, electronic grade surge
protective device designed with sine wave tracking to protect electronic equipment and
microprocessor-based systems from transients on distribution panels, branch panels, or equipment in
low exposure locations. Dry contacts for remote indication standard.



















AC Power Low Exposure TVSS Technical Specification

Connection Type ................................................. Parallel
Operating Voltage Range................................... +/-15%
Fault Current Rating (AIC).................................. 14 kAIC
Dimensions ..................... .................................... 4.72”x4.72”x2.36”
Operating Frequency Range ............................. 47 – 63 Hz
Capacity................................................................ Continuous
50 EMI/RFI Attenuation ................................... 40 dB
Response Time.................................................... <0.5 ns
Dry Contract rating.............................................. 125vac, 8.0A, 1.0pf
Operating Temperature ...................................... -40ºc to +50ºc
Operating Humidity............................................. 0% to 95%
Status Indication.................................................. LED, Dry Contacts
Certifications........................................................ UL 1449, CUL, CE, ISO 9001
Warranty ............................................................... 5 Years

UL 1449 (second edition) Classification

120

volt

systems.................................400 volts all modes

208 through 277 volt systems ..........800 volts all modes

480

volt

systems.................................1,500 volts all modes

ORDERING INFORMATION

Building A Model Number: LPL 1 2 3

1: Nominal Voltage Requirements

2: System Configuration

3: Surge Current Capacity

Nominal Voltage Requirements

Model ID

System Configuration

Model ID

L-N

L-L

L-G

120 ........N/A....... 120

120

Single (2 Wire + Gnd)

N or L

120 .......208 ...... 120

120

Split (3 Wire + Gnd)

S

120 ........240....... 120

120

Wye (4 Wire + Gnd)

Y

N/A ........208....... 208

208

Delta Hi-Leg (4 Wire + Gnd)

H

230 ........400....... 230

230

Delta (3 Wire + Gnd)

D

N/A ........240....... 240

240

277 ........480....... 277

277

N/A ........400....... 400

400

N/A ........480....... 480

480

Surge Current Capacity

Model ID

100 kA/Phase

100

(L-N: 50 kA + L-G: 50 kA; N-G: 50 kA)

50 kA/Phase

50

(L-N: 25 kA + L-G: 25 kA; N-G: 25 kA)

PANEL I.D.

MODEL NUMBER(S)

25 kA/Phase

25 – 2

(L-N: 25 kA; N-G: 25 kA)



Job Name _______________________

Model # _________________________

Date ___________________________

Qty ____________________________

Quote # _________________________

Advertising
This manual is related to the following products:
Table of contents