KEEPING YOUR SYSTEM IN TOP FORM-CONT.

HM30 Temperature / Pressure Relief Valve Testing

This valve is a safety device to protect
against abnormally high temperature
and pressures. Periodic discharge of
the relief valve may indicate thermal
expansion within a closed system.
A thermal expansion tank will be needed to
allow water to expand.
If the valve discharges, it is doing so because there is
a problem. Call your Lennox dealer or qualified
technician to inspect the unit for proper
operation. Do not ignore the water disĆ
charge. Never plug the T&P relief valve.

WARNING

Danger of Personal Injury from Scalding.

Water from T&P relief valve may be exĆ

tremely hot and is not tempered. Use exĆ

treme caution when discharging valve. ReĆ

placement of T&P valve should be done by

a trained professional or a licensed plumbĆ

ing contractor.

T&P valve testing should be done annualĆ
ly. Remove HM30 top access panel. LoĆ
cate the temperature and pressure relief
valve.
Test the T&P valve by lifting the lever
up until the valve unseats. This allows
the water to discharge. Never open the T&P valve unless it is connected to a discharge line.
If water does not flow, valve may be obstructed or corroded. Call your Lennox dealer or qualified techniĆ
cian to inspect the valve.

Drain

T&P Valve

Drain Line

WARNING - Water from

valve may be extremely hot.

Use extreme caution when

discharging valve.

TEMPERATURE / PRESSURE (T&P) RELIEF VALVE

TESTING PROCEDURE

Test Lever

(Lift up to discharge water)

Temperature & Pressure

Relief Valve

Drain Line

HM30

Unit

HM30 Top

Access Cover