LOCATION OF FIREPLACE

Carefully select the proper location for heat
circulation, aesthetics, chimney obstructions
and clearance to side wall(s). With proper pre-
planning, a slight adjustment of a few inches
can save considerable time and expense later
during construction and assembly.

Chase Enclosure

A chase is a vertical box-like structure con-
structed to surround the fireplace and chimney.
Refer to

Figure 2 for a typical chase configura-

tion. As with all chimney installations, avoid
overhead obstructions such as trees, power
lines, etc. A chase should be constructed and
insulated just like any outside wall. In a cold
climate, we recommend the base of the chase
should also be insulated between the solid
continuous floor beneath the fireplace and the
chase bottom. Chase insulation in a cold cli-
mate installation is not required for safety.

ASSEMBLY OUTLINE
Before You Start

Check your inventory list to be sure you have all
the necessary parts supplied in good usable
condition. Check also for any concealed damage.

Check the operation of the damper. The damper
is controlled through the use of a control lever
located within the firebox opening at the top
center just behind the firebox lintel (

Figure 3 ).

Push back and up (away from the front of the
fireplace) to lock the damper blade in the
OPEN position. To lock the damper in the
CLOSED position, the damper handle needs
to be pulled forward and up (towards the
front of the fireplace).

Figure 3

Insulate Joists

Same as Ceiling

Draft Stops

F10FS-2 Firestop

FTF10-CTDTM

Termination

Note: Non-

Combustible

Chase

Flashing

Must be

Used to

Cover

Chase

Opening

Optional

Insulation

in Outside

Walls of

Chase

Solid

Continuous

Surface

Outside

Base

Insulation
(Thermal Barrier)

8'

(2.4m)

Level

Hearth

Hearth

Optional

Outside

Chase

Figure 4

Carefully consider the position of the fireplace
opening with respect to the location of adja-
cent or nearby stairwells, bath or kitchen ex-
haust fans and/or return air registers for forced
air furnaces/air conditioners that could cause
a smoking fireplace condition if the house is
tightly insulated.

When locating the fireplace, consideration must
be given to combustibles and final finishing.
See

Figure 5 and confine the final location of

combustible finish materials to the "Safe Zone".

Damper

Closed

Damper
Open

Lintel

Combustion
Air Actuator

Note: Do not insulate the chase cavity with
blown or fill type insulation materials.

CHIMNEY HEIGHT

The total height of your completed fireplace sys-
tem from the surface the fireplace rests on to the
chimney top must not exceed 80' (24.4m) and
must also meet minimum height requirements.
Refer to the minimum system height chart.

Minimum System Height

Security's FTF10 Pipe

Vertical

16' 0"

Installation

(4.8 m)

One

18' 6"

Offset

(5.6 m)

Two

22' 0"

Offsets

(6.7 m)

Note: Local codes may not require firestopping
at the ceiling levels for outside chase installa-
tions. However, it is recommended for safety
and the reduction of heat loss.

WARNING: IF INSULATION IS USED, THE
FIREPLACE MUST NOT BE PLACED DI-
RECTLY AGAINST IT. INSULATION OR
VAPOR BARRIERS, IF USED, MUST FIRST
BE COVERED WITH GYPSUM BOARD,
PLYWOOD, PARTICLE BOARD OR OTHER
MATERIAL TO ASSURE INSULATION AND
VAPOR BARRIERS REMAIN IN PLACE.

WARNING: DO NOT PACK OR FILL RE-
QUIRED AIR SPACES WITH INSULATION
OR OTHER MATERIAL. NO MATERIAL IS
ALLOWED IN THESE AREAS.