Lowrance electronic LMS-520C User Manual

Page 239

Advertising
background image

229

Highlight

C

ALIBRATE

T

RIM

and press

ENT

. The Device Calibration window

will appear with a list of Calibration Instructions.
4. Highlight

S

TART

C

ALIBRATION

and press

ENT

. The following message

will appear: Please fully raise the Engine Trim.
5. After engine trim has been fully raised, press

ENT

. The following

message will appear: Please fully lower the Engine trim.
6. After engine trim has been fully lowered, press

ENT

. A Calibration

Completed message will appear. Press

ENT

.

7. Repeat these instructions to adjust the engine trim for each engine

connected to a Suzuki Engine Interface. Press

EXIT

repeatedly to return

to the main display.
Reset Trim Calibration
If you are not satisfied with your engine trim calibration, you can reset

engine trim calibration from the Suzuki Engine Interface Advanced

Options menu.
1. Press

MENU

|

MENU

, select

NMEA

2000

and press

ENT

.

2. Choose

B

US

S

ETUP

and press

ENT

. Select the Suzuki Engine Interface

connected to the desired engine and press

ENT

.

3. Highlight

A

DVANCED

O

PTIONS

and press

ENT

. Select Reset

T

RIM

C

ALIBRA-

TION

and press

ENT

. The following message will appear: Do you wish to

re-calibrate the device?
4. Highlight

Y

ES

and press

ENT

. Press

EXIT

repeatedly to get back to the

main display.

Bennett Trim Tabs Calibration
Trim Tabs will be calibrated through their Device Configuration menu.

To calibrate Trim Tabs:

1. Press

MENU

|

MENU

, select

B

US

S

ETUP

and press

ENT

. A list of network

devices will appear.
2. Select

B

ENNETT

T

RIM

T

ABS

from the list and press

ENT

, which will open

the Trim Tab Device Configuration menu.
3. Highlight

C

ALIBRATE

and press

ENT

. The Device Calibration window

will appear with a list of calibration instructions.
4. Select

S

TART

C

ALIBRATION

and press

ENT

. The following message will

appear: Please fully raise Trim Tabs.
5. After fully raising the trims tabs, press

ENT

. The following message

will appear: Please fully lower trim tabs.
6. After fully lowering the trim tabs, press

ENT

. A Calibration Complete

message will appear. Press

ENT

. Press

EXIT

repeatedly to return to the

main display.