Thermostat operation, Vent safety shutoff system, Reversible vertical or horizontal draft diverter – Langley/Empire RH-25-6 User Manual

Page 8

Advertising
background image

Page 8

12821-6-0406

This heater must be properly connected to a venting system. This

heater is equipped with a vent safety shutoff system.

Warning:

Operation of this heater, when not connected to a properly

installed and maintained venting system or tampering

with the vent safety shutoff system, can result in carbon

monoxide (CO) poisoning and possible death.

This appliance needs fresh air for safe operation and must be

installed so there are provisions for adequate combustion and

ventilation air.

This room heater is equipped with a vent safety switch. The vent

safety switch will cause gas flow to the pilot to “shut off” due to

improper venting or a blocked flue.
If the vent safety switch continues to “shut off” the gas flow to

the pilot a qualified service person must be contacted to inspect

for improper venting, blockage in the vent pipe or the vent safety

switch for being defective.

DRAFT DIVERTER CAN BE EITHER A VERTICAL VENT

OR HORIZONTAL VENT

Figure 4

This room heater has a reversible draft diverter. The draft diverter

is installed in the vertical position at the factory. Please use the

following steps to change the draft diverter from the vertical posi-

tion to the horizontal position.
1. Remove L280 vent safety switch from the draft diverter.

2. Inside your yellow instruction envelope will be a 1 1/2" x 2 1/4"

(38mm x 51mm) vent safety switch hole cover plate and two

(2) 1/2" screws for attachment of vent safety switch hole cover

plate to the draft diverter. Attach vent safety switch hole cover

plate over hole on the draft diverter from which the L280 vent

safety switch was removed.

3. Remove two (2) screws at bottom of draft diverter and lift

upward to remove draft diverter from the draft diverter plate.

Rotate draft diverter into the horizontal position and slide back

into the draft diverter plate. Attach two (2) screws into bottom

of the draft diverter.

4. Remove vent safety switch hole knockout and two (2) knockouts

for screws on opposite side of draft diverter.

5. Attach L280 vent safety switch to the draft diverter.

6. Repositioning of the draft diverter is completed.

Thermostat Operation

To turn on burner, rotate dial knob toward setting number 7. To

shut down burner, rotate dial knob toward number 1.
The dial numbers 1 through 7 correspond to 50° (10°C) through

90°F (32°C). This is the temperature at the bulb thermostat not the

room temperature. The owner is advised to determine the particular

heat setting that is desired for comfort, as heating requirements are

different for every owner.

Attention: If no heat is desired, turn the gas control knob to the

PILOT position.

THERMOSTAT OPERATION

REVERSIBLE VERTICAL OR HORIZONTAL DRAFT DIVERTER

VENT SAFETY SHUTOFF SYSTEM

Advertising