(1) Output rating in watts is equivalent to volt-amperes at unity power factor. Output voltage is within ± 10% at all loads up to rated capacity.

When welding, available auxiliary power will be reduced.

(2) Reduced to less than 30V in the CC-stick Mode when VRD (VOLTAGE REDUCTION DEVICE) is on.

(3) Maximum per circuit breaker rating.

(4) To Top of enclosure. Add 7.35 (186.7mm) to top of exhaust. Add 3.87”(98.3mm) to top of Lift Bail.

A-1

INSTALLATION

A-1

TECHNICAL SPECIFICATIONS - VANTAGE® 500 (K2686 -1)

Make/Model

Description

Speed (RPM)

Displacement

Starting

Capacities

cu. in. (ltrs.)

System

4 cylinder

135.6(2.2)

12VDC Battery &

Fuel: 20 gal.

43 HP

High Idle 1850

starter

(75.7 L)

PERKINS

1850 RPM

Bore x Stroke inch (mm)

(Group 34; 650 Oil: 8.45Qts. (8L)

404D-22T Turbo Charged

Full Load 1850 cold crank amps)

water cooled

3.43 X 3.64

65 Amp Alternator

Radiator Coolant:

Diesel Engine

Low Idle 1400

(87.1 x 92.5mm)

W / Built in Regulator

11.5 Qts. (10.9L)

INPUT - DIESEL ENGINE

RATED OUTPUT @ 104° F (40° C) - WELDER

LUBRICATION EMISSIONS

FUEL SYSTEM

GOVERNOR

Full Pressure

EPA Tier 4

Mechanical Fuel Pump, Auto air bleed

Electronic

with Full Flow Filter

Interim Compliant system, Electric shutoff solenoid, Indirect fuel injection.

AIR CLEANER

ENGINE IDLER

MUFFLER

ENGINE PROTECTION

Low noise Muffler:

Shutdown on low oil

Single Element

Automatic Idler

Top outlet can be rotated. pressure & high engine

Made from long life, aluminized steel. coolant temperature

ENGINE WARRANTY: 2 years / 2000 hours, all non-electric components, 3 years major non-electric compo-
nents . See Perkins warranty for details.

Welding Process

DC Constant Current

DC Pipe Current

Touch-Start™TIG

DC Constant Voltage

Arc Gouging

Output Range

30 TO 525 AMPS

40 TO 300 AMPS
20 TO 250 AMPS

14 TO 40 VOLTS

90 TO 500 AMPS

Max. Weld OCV

@Rated Load RPM

60 Volts

(2)

60 Volts

Welding Output

Current/Voltage/Duty Cycle

500A / 40V / 100%

525A / 38V / 60%

300A / 32V / 100%
250A / 30V / 100%
500A / 40V / 100%

525A / 38V / 60%

500A / 40V / 100%

Auxiliary Power

(1)

13,000 Watts Peak / 12,000 Watts Continuous, 60 Hz 120/240 Volts Single Phase

22,000 Watts Peak / 20,000 Watts Continuous, 60 Hz 240 Volts 3 Phase

ENGINE

RATED OUTPUT @ 40° C (104° F)

.

- GENERATOR

HEIGHT WIDTH

DEPTH

WEIGHT

35.94

(4)

in. 27.05 in 62.59 in.

913 mm

687 mm

1590 mm

PHYSICAL DIMENSIONS

1290 lbs. (586kg.)