Troubleshooting Guide

When Vertical Louver does not operate.

• Confirm that the Vertical Louver is normally geared with the shaft of

Stepping Motor.

• If the regular torque is detected when rotating the Vertical Louver with

hands

Normal

• Check the connecting condition of CN-UP/DOWN Connector
• Check the soldering condition(on PWB) of CN-UP/DOWN Connector

Check the operating circuit of the Vertical Louver

• Confirm that there is DC +12V between pin

(RED) of CN-UP/DOWN and

GND.

• Confirm that there is a soldering short at following terminals.

- Between

60

,

61

,

62

and

63

of MICOM

- Between

2

,

3

,

4

and

5

of IC01M

- Between

12

,

13

,

14

,

15

of IC01M

- Between

1

,

2

,

3

,

4

and

5

of CN-UP/DOWN

If there are no problems after above checks

• Confirm the assembly conditions that are catching and interfering parts in

the rotation radial of the Vertical Louver