Tape the drain hose and the connecting cable, Indoor unit installation – LG LSU120HE User Manual

Page 23

Advertising
background image

Service Manual 23

Insert the connecting cable into the indoor
unit.

• Don't connect the cable to the indoor unit.

• Make a small loop with the cable for easy con-

nection later.

Tape the drain hose and the connecting cable.

• Connecting cable

Connecting the pipings to the indoor unit
and the drain hose to drain pipe.

• Put a couple drops of refrigerant oil on the face

of the flare before assembling taking care not to
add any contaminants

• Align the center of the pipings and sufficiently

tighten the flare nut by hand.

• Tighten the flare nut with a wrench.

Indoor unit tubing

Flare nut

Pipings

Torque wrench

Indoor unit tubing

Spanner (fixed)

Connection pipe

Flare nut

Indoor unit installation

• Hook the indoor unit onto the upper portion of

the installation plate.(Engage the three hooks of
the rear top and rear lower of the indoor unit with
the upper edge and lower edge of the installation
plate.) Ensure that the hooks are properly seated
on the installation plate by moving it left and
right.

Vinyl tape

Adhesive

Drain hose

Indoor unit drain hose

(narrow)

• When extending the drain hose at the indoor

unit, install the drain pipe.

Connecting
pipe

Connecting cable

Tape

Drain hose

Drain hose

Connecting

cable

Ш6.35

1/4

1.8

Ш9.52

3/8

4.2

Ш12.7

1/2

5.5

Ш15.88

5/8

6.6

Outside diameter

Torque

• Mount the clamp on the boss with a type "B"

screw.(SE-H/P: 9k, 12k C/O: 12k)

Drain hose

Clamp

Boss

Type "B" screw

Wrap the insulation material around the
connecting portion.

• Overlap the connection pipe heat insulation and

the indoor unit pipe heat insulation material.
Bind them together with vinyl tape so that there
is no gap.

Plastic bands

Insulation material

Advertising