Be sure to deburr the ends with a file after cutting. Installation is

easy after cutting the wall opening secure the vent terminal box

in place using the (4) 10 x 1" hex-head screws provided. Locate

the box so that the middle exhaust tube is directed toward the

furnace exhaust outlet opening. See Figure 8. Attach the black 2"

flexible inlet air hose to the bottom 2" connector on the vent box

using a hose clamp. Secure the other end to the lower inlet air

box connector using the hose clamp. Do not kink hose. Attach the

long straight end of the 2" orange silicone exhaust elbow to the

middle vent terminal tube and rotate the elbow toward the furnace

exhaust outlet. Secure the hose to the vent box using a hose clamp.

Carefully push the furnace back closer to the wall and secure the

exhaust elbow to the 2" exhaust tube exiting the unit. Secure the

elbow in place using the last remaining hose clamp. The furnace

can now be secured to the wall.
The furnace can be vented with up to a maximum length of 15'

(4.6m) including termination vent and using 2 - 90° elbows. Also,

the furnace can be vented with up to a maximum length of 10'

(3m) including termination vent and using 3 - 90° elbows. For

longer vent lengths order the vent kit, Part Number DVE-1 and

DVE-2. See Figures 11 and 12 illustrating extended vent run and

venting options.
Note: If the extended vent kit is used and the exhaust vent pipe

is run through a cold space, such as an attic or a garage, the pipe

should be insulated using 1/2" (13mm) thick fiberglass insulation

or equivalent to keep the flue products warm enough to avoid

condensation. Also, slope 1/4" (6mm) per foot (305mm) the vent

terminal horizontal run downward toward the outside of the house

to assure any condensate flow out of vent system. Horizontal

vent pipe runs of 5 feet (1.5m) or more in length may accumulate

condensation in the exhaust pipe and must, therefore, be sloped

downward to drain any condensate out of the end vent terminal.

Use straps or other suitable supports spaced every 5 feet (1.5m) to

adequately hold pipe. Be sure to avoid any low spots or sags in

pipe run. Be sure all connections are tight using the hose clamps

as shown in Figure 9, "Vent Coupling Connections."
For wall depths thicker than 10" (254mm) order the extended vent

terminal kit which will cover walls to 32" (813mm) thickness.

The vent pipes must be cut to length to assemble for desired wall

thickness.
For extended venting, it is also acceptable to use 2" (51mm) diameter

PVC or ABS pipe for the combustion air intake supply piping

only to the unit. If this is used, the pipe and fittings must conform

to ANSI and ASTM Standards D1785 for SCH. 40 PVC, D2665

for PVC-DWV, D2241 for SDR-21 and SDR-26 PVC, D2661 for

ABS-DWV and F628 for SCH. 40 ABS. Pipe cement and primer

must be used and conform to ASTM Standard D2564 for PVC or

D2235 for ABS. This PVC or ABS pipe must not be used for

the exhaust vent pipe run.
Note: Type SDR pipe is not approved for use in Canada.
For new construction installation, the intake and exhaust vent

can be run inside a wall, a vertical or horizontal distance prior to

exiting the wall. This can be done but not the preferred method of

installation due to the inability to perform periodic inspection of

the vent system. In doing this, it is important to securely seal the

vent system and slope all horizontal runs downward 1/4" (6mm)

per foot (305mm) toward the vent terminal outside to drain out

any condensate. It is also necessary to adequately support both the

exhaust and intake and to center the exhaust pipe in the wall.
Be sure to consult local codes prior to installation to verify allowable

procedures.
Installation of Shroud

To complete inside installation, secure furnace to the wall bracket

by attaching the two wall mounting brackets to the wall bracket

by using (2) 10 x 1/2" (13mm) hex-head screws provided (See

Figures 4 and 6). To attach the right shroud and left shroud to the

casing back, the 3/4" wide flange on the shroud must be positioned

toward the casing side. When positioned correctly, the (6) louvers

on the shroud will be facing up and the knock-out on the shroud

will be facing down. Attach the right shroud and left shroud to the

casing back with (3) 10x1/2" hex-head screws supplied in hardware

package, for each shroud. Attach top shroud to right shroud and

left shroud with (4) Phillips-head screws, supplied in hardware

package. Insert air filter into top shroud.
Attention: If the right shroud and left shroud are installed incorrectly,

with the 3/4" wide flanges facing inward, the top shroud will not

be able to be installed onto the side shrouds. The top shroud will

appear to be 2 inches, too narrow.
Vent Terminal (Figure 10)

Place the 6 3/8" x 6 3/8" (162mm x 162mm) black foam, wall plate

gasket within the mounting plate. The 4 3/4" (121mm) diameter

hole in the black foam gasket will allow for installation of the

concentric vent tube assembly. Slide the outside mounting plate into

place on the concentric vent tube assembly. The outside mounting

plate should seal against the face of the building and be secured

in place using (4) 10 x 1" hex-head screws. Be sure to caulk and

seal around the pipe on the exterior using high temperature exterior

grade, silicone caulk rated at 204°C/400°F. Wipe some silicone

sealant on the 2" (51mm) exhaust pipe extension. The end cap can

be pushed into place on the exhaust outlet tube.
Attention: The opening on the bottom of the end cap must be

positioned toward the ground. The opening on the bottom cannot

be pivoted to the right or left, it must be centered toward the

ground.

Figure 10

NO. 10 X 1 1/2"

SCREWS (4)

INLET AIR

EXHAUST

AIR

12"(305mm)MIN.

ABOVE GRADE

CAULK AROUND PIPE

EXHAUST FITTING-SLIDE ONTO

2" EXHAUST TUBE AND USE RTV

SEALANT TO SECURE IN PLACE

WITH OUTLET POINTED DOWN

AS SHOWN

FURNACE INSTALLATION (continued)