Installation – Lincoln Electric IM839 User Manual

Page 9

Advertising
background image

A-2

INSTALLATION

DEVICENET MODULE

A-2

Install the DeviceNet bulkhead connector by removing
the plastic plug covering the circular hole (ITEM 4) in
the front lower panel assembly. Install the 5-pin con-
nector and mounting plate over the mounting studs as
shown in (Figure A.1). Fasten with two of the supplied
locknuts.

If a Wire Drive Interface Module is not installed
(Figure A.1), locate the 6-pin to 4-pin interconnect.
Insert the interconnect between J73 on the DeviceNet
module and J16 in the machine harness. Discard the
4-pin to 4-pin interconnect and proceed to the next
section.

If a Wire Drive Interface Module is installed (Figure
A.2), locate the 4-pin to 4-pin interconnect. Insert the
interconnect between J73 on the DeviceNet module
and J81 on the Wire Drive Interface Module. Discard
the 6-pin to 4-pin interconnect.

DeviceNet Baud rate: The default Baud rate is 125K.
If another Baud rate is desired, see table 2 in this sec-
tion and set switches 1 and 2 of bank S2. Every
device on a DeviceNet network must have the same
Baud Rate.

DeviceNet Module DIP Switches:

Bank S1

switch 1 = Object Instance LSB (Default = OFF)
(See Table 1)
switch 2 = Object Instance MSB (Default = OFF)
(See Table 1)

Object Instance (Table 1)

Switch 2

Switch 1

Instance

Off

Off

0

Off

On

1

On

Off

2

On

On

3

switch 3 = Equipment Group 1 Select (Default = Off)
switch 4 = Equipment Group 2 Select (Default = Off)
switch 5 = Reserved for future use
switch 6 = Reserved for future use
switch 7 = Reserved for future use
switch 8 = Reserved for future use

Bank S2

switch 1 = DeviceNet Baud Rate (Default = OFF)
(See Table 2)
switch 2 = DeviceNet Baud Rate (Default = OFF)
(See Table 2)

DeviceNet Baud Rate (Table 2)

Switch 1

Switch 2

Baud Rate

Off

Off

125K

On

Off

250K

On

On

500K

On

On

Programmable Value

switch 3 = DeviceNet Mac ID (Default = Off)
(See Table 3)

switch 4 = DeviceNet Mac ID (Default = On)
(See Table 3)

switch 5 = DeviceNet Mac ID (Default = On)
(See Table 3)

switch 6 = DeviceNet Mac ID (Default = On)
(See Table 3)

switch 7 = DeviceNet Mac ID (Default = On)
(See Table 3)

switch 8 = DeviceNet Mac ID (Default = On)
(See Table 3)

DeviceNet MAC ID:

The default Mac ID is 62. Every device on the
DeviceNet network should have a unique ID. If anoth-
er MAC ID is desired, refer to Table 3.

Complete Board Installation

Close door assembly insuring not to cut or
pinch any wires.

Reinstall the screws in door assembly.

Re-apply power and verify the appropriate
status lights on the Power Wave are green.
Discard any remaining hardware.

4-pin to 4-pin interconnect

Wire Drive Module

ONLY FOR MACHINES WITH A DEVICENET MODULE

AND A WIRE DRIVE INTERFACE MODULE

FIGURE A.2

Advertising