Linear TMD-90 User Manual

Tmd-90, Installation instructions

Advertising
background image

INS

T

R,INS

T

,TMD-90

Linear P

/N: 208457 E

Material: 20 Lb. Mead B

ond

S

ize: 8.500" x 11.000"

Ink: B

lack

S

c

ale: 1-1

Front S

ide 1 of 2

TMD-90

SUPERVISED WIRELESS
PASSIVE INFRARED
MOTION DETECTOR

Installation Instructions

(760) 438-7000

• FAX (760) 438-7043

USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

DESCRIPTION

The TMD-90 is a passive infrared (PIR)

motion detector with a built-in supervised, digitally-coded radio
transmitter designed for security applications.
The PIR detects motion in its detection pattern by measuring the
infrared emission levels of objects that it “sees”. If the infrared levels
change quickly, as when a person moves across the detection
pattern, the PIR will recognize the change as an intrusion.
A selectable “pulse count” circuit controls the PIR’s triggering of the
transmitter. As a person moves across the detection pattern, the PIR
registers one pulse as each “finger” of the detection pattern is
crossed. The TMD-90 counts these pulses. When the selected
number of pulses occur during the selected time, the PIR will trigger
the transmitter, sending an alarm signal. A lockout timer prevents the
transmitter from triggering more often than once every 2 minutes
when constant motion is detected. The pulse counting and timing
options are selected with the OPTION switch.
The unit is supervised for low battery, alarm and status reporting. The
TMD-90 is compatible with any Linear SX format supervised
security receiver.
The transmitter sends hourly status reports. A test
report can be sent by pressing the test button.
Coding switches are not required or used in this transmitter. Each
transmitter is pre-coded at the factory to a unique code. With the SX
format, there are more than sixteen million codes possible.

The transmitter is powered by four Duracell “AA” MN1500 1.5-volt
alkaline batteries (included) and can power the unit for up to 5 years.
When the battery voltage gets low, a low battery report is sent to the
receiver with any alarm, test or status report.

STEP 1

Open detector case. Press in the locking tab and

remove the case cover.

STEP 2

Identify components. Examine the unit to identify

the various components.

STEP 3

Remove circuit board. Remove the adjustment

post and remove the circuit board.

STEP 4

Punch out knockouts. Use a small Phillips

screwdriver to punch out the desired case mounting knockouts.

STEP 5

Mount case. Attach the case to the wall using the

screws and screw anchors provided. Mount the detector in a
location where the intruder’s path will likely cross the
detection pattern beams.

STEP 6

Replace board. Replace the circuit board and

install the adjustment post. Center the detection pattern pointer.
Remove the battery protection strip.

STEP 7

Set option switches. Set the option switches to

select the number of pulses and time frame for alarm. Set
switches 2 & 5 ON, 1, 3 & 4 OFF. Set switch #6 ON to select
walk test mode.

STEP 8

Replace cover. Replace the case cover. Press the

bottom edge until the locking tab engages.

SX

FORMAT!

TOP VIEW

SIDE VIEW

7.5'

(2.29 M)

A

B

C

D

D

C

B

A

40' (12.19 M)

40

' (1

2

.19

M

)

A = CREEP ZONES
B = SHORT RANGE ZONES
C = INTERMEDIATE ZONES
D = MAIN ZONES

DETECTION
PATTERN

WINDOW

HEAT

&

COLD

DON'T AIM

AT GLASS

DON'T AIM

AT HEATER

DON'T MOUNT

NEAR VENT

DON'T ALLOW

DIRECT SUNLIGHT

INSTALLATION TIPS

PUSH IN
LOCKING TAB

OPEN
CASE

ANTENNA

TRANSMITTER
TEST BUTTON

TAMPER
SWITCH

OPTION
SWITCH

ADJUSTMENT
POST

WALK TEST
LED

INFRARED
DETECTOR

FOUR TYPE "AA"
BATTERIES

BATTERY
PROTECTION
STRIP

REMOVE
ADJUSTMENT
POST

SLIDE CIRCUIT
BOARD UP
TO REMOVE

PUNCH OUT
SIDE KNOCKOUTS
FOR CORNER MOUNTING

PUNCH OUT
BACK KNOCKOUTS
FOR WALL MOUNTING

LAY BASE ON
CARPET AND
PUNCH OUT
KNOCKOUTS
WITH PHILLIPS
SCREWDRIVER

APPROXIMATELY
7 FEET FROM FLOOR

ARROW ON
CASE POINTS
TO TOP

USE SCREWS AND
ANCHORS TO MOUNT
CASE TO WALL

REPLACE
ADJUSTMENT
POST

CENTER DETECTION
PATTERN POINTER
ON ADJUSTMENT
POST

REMOVE THE
BATTERY
PROTECTION
STRIP

NOTE:

USE DURACELL

MN1500 OR

TOSHIBA LR6G

"AA" ALKALINE

BATTERIES

ONLY!

LOCKING TAB
WILL SNAP SHUT

CLOSE
CASE

SWITCHES 1, 2 & 3

SET NUMBER OF PULSES

2 PULSES
3 PULSES
5 PULSES

ON

OFF
OFF

OFF

ON

OFF

OFF
OFF
OFF

#1

#2

#3

OPTION SWITCH

SWITCHES 4 & 5 SET TIME

THAT PULSES MUST OCCUR

8 SECONDS

16 SECONDS
32 SECONDS

ON

OFF
OFF

OFF

ON

OFF

#4

#5

SET

SWITCH

#6 ON FOR

WALK TEST

Advertising