Installation, Technical specifications – weldmark 135 plus – Lincoln Electric WELDMARK 135 PLUS IM789 User Manual

Page 8

Advertising
background image

A-1

A-1

INSTALLATION

Fuse or

Output Mode

Input Voltage

Breaker Size

Input Amps

Extension Cord

Three Conductor

#14 AWG

RATED

115V/60Hz

20 Amp

20

(2.1 mm

2

) or Larger

for up to

25 feet (7.6m)

Three Conductor

#12 AWG

MAXIMUM

115V/60Hz

25 Amp

25

(3.3 mm

2

) or Larger

for up to

50 feet (15.2 m)

TECHNICAL SPECIFICATIONS – WELDMARK 135 PLUS

INPUT – SINGLE PHASE ONLY

RATED OUTPUT

OUTPUT

RECOMMENDED INPUT CABLE AND FUSE SIZES

Height

Width

Depth

Weight

12.0 in

9.75 in

16.5 in

54 Ibs

305 mm

248 mm

419 mm

24.3 kg

PHYSICAL DIMENSIONS

Standard Voltage/Frequency

Input Current

115V/60Hz

20 Amps - Rated Output

115V/60Hz

25 Amps - Maximum Output

115V/60Hz

15 Amps - CSA Rated output

Duty Cycle

Amps

Volts at Rated Amperes

20% Duty Cycle – Rated DC Output

90

18

Welding Current Range (Continuous)

Maximum Open Circuit Voltage

Auxiliary Power

Rated DC Output: 25 – 135 Amps

28

N/A

WELDMARK 135 PLUS

Advertising