Piping length and elevation – LG LS122CE User Manual

Page 14

Advertising
background image

14 Room Air Conditioner

Installation

Piping Length And Elevation

• Capacity is based on standard length and maximum allowance length is on the basis of

reliability.

• Oil trap should be installed every 5~7meters (16.4~23.0ft).

Pipe Size

Capacity

(Btu/h)

Suction

Evap

Max.

length

A

m(ft)

Additional Refrigerant

g/m(oz/ft)

Max.

Elevation

B

m(ft)

Standard

Length

m(ft)

In case more than 5m(16.4ft)

Outdoor unit

Indoor unit

A

B

Outdoor unit

Indoor unit

A

B

A

Oil trap

Outdoor unit

Indoor unit

B

9k

3/8"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)

1/2"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)

12k

1/2"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)

18k

1/2"

1/4"

7.5(25)

15(49)

30(98)

20(0.22)

5/8"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)

24k

5/8"

1/4"

7.5(25)

7.5(25)

15(49)

20(0.22)