Moose z1100, Caddx ranger 9000, C&k 236 – Linear SXR-64A User Manual

Page 2: Napco ma1000e

Advertising
background image

Copyright © 2003 Linear Corporation

220822 A

ERASING SINGLE-CHANNEL TRANSMITTERS

ERASING MULTI-BUTTON TRANSMITTERS

SETTING RECEIVER OPTIONS

TRANSMITTER COUNT

VERIFYING TRANSMITTERS

SYSTEM TESTING

HOOKUP: MOOSE Z1100 & CADDX RANGER 9000

HOOKUP: C&K 236 & NAPCO MA1000

LINEAR LIMITED WARRANTY

This Linear product is warranted against defects in material and workmanship for twelve (12)
months. The Warranty Expiration Date is labeled on the product. This warranty extends only
to wholesale customers
who buy direct from Linear or through Linear’s normal distribution
channels. Linear does not warrant this product to consumers. Consumers should inquire from
their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or
liabilities on the part of Linear Corporation for consequential damages arising out of or in
connection with use or performance of this product or other indirect damages with respect
to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation.

All implied warranties, including implied warranties for merchantability and implied warranties
for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear
Corporation Warranty is in lieu of all other warranties express or implied.

All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

IMPORTANT !!!

Linear radio controls provide a reliable communications link and fi ll an important need in portable
wireless signalling. However, there are some limitations which must be observed.

✶ For U.S. installations only: The radios are required to comply with FCC Rules and Regulations

as Part 15 devices. As such, they have limited transmitter power and therefore limited range.

✶ A receiver cannot respond to more than one transmitted signal at a time and may be blocked

by radio signals that occur on or near their operating frequencies, regardless of code
settings.

✶ Changes or modifi cations to the device may void FCC compliance.
✶ Infrequently used radio links should be tested regularly to protect against undetected

interference or fault.

✶ A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale

distributor or dealer, and these facts should be communicated to the ultimate users.

ENTERING SINGLE-CHANNEL TRANSMITTERS

ENTERING MULTI-BUTTON TRANSMITTERS

SETTING TRANSMITTER OPTIONS

PRINTER’S INSTRUCTIONS:

INSTR,INSTL,SXR-64A - LINEAR P/N: 220822 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 17.000” - SCALE: 1-1 - SIDE 2 OF 2

OR

RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (1 SHOWN)

MEMORY LIGHT WILL BE OFF IF THE RECEIVER
CHANNEL IS VACANT (ONLY A VACANT RECEIVER
CHANNEL CAN ACCEPT A TRANSMITTER)

PRESS [MEMORY]

MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ACCEPT A TRANSMITTER

ACTIVATE THE TRANSMITTER

THE MEMORY LIGHT WILL GO ON, SHOWING
THAT THE TRANSMITTER WAS ENTERED AND
THE RECEIVER'S DISPLAYED CHANNEL IS OCCUPIED

WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
UNTIL THE DESIRED RECEIVER CHANNEL
NUMBER (1-64) IS DISPLAYED

CHANNEL

ZONE

CHANNEL

ZONE

PRESS [ADVANCE] TO SELECT THE OUTPUT ZONE
NUMBER (1-8) FOR THE DISPLAYED
RECEIVER CHANNEL NUMBER

RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (3 SHOWN)

NOTE: ARMING THE CONTROL PANEL ANYTIME

DURING PROGRAMMING WILL CAUSE THE SXR-64A TO

EXIT PROGRAM MODE AND RETURN TO RUN MODE

OR

RECEIVER CHANNEL NUMBER (64 SHOWN)
IGNORE ZONE NUMBER (3 SHOWN)

MEMORY LIGHT WILL BE ON, SHOWING THAT THE
RECEIVER CHANNEL IS OCCUPIED

PRESS [MEMORY]

MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ERASE A TRANSMITTER
FROM THE DISPLAYED RECEIVER CHANNEL

PRESS [MEMORY] AGAIN

MEMORY LIGHT WILL GO OFF, SHOWING
THAT THE TRANSMITTER HAS BEEN ERASED
AND THAT THE RECEIVER'S CHANNEL IS VACANT

WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH
THE SINGLE-CHANNEL TRANSMITTER TO ERASE

CHANNEL

ZONE

OR

WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")

"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTIONS)

PRESS [ADVANCE] UNTIL THE DESIRED FUNCTION
LETTER (1-d) IS DISPLAYED

CONFIGURATION OPTION DISPLAYED
(FUNCTION "b" SHOWN)

Fn #

MEMORY LIGHT

OFF

MEMORY LIGHT

ON

ARMED WHEN
ARM=GROUND

ARMED WHEN
ARM=VOLTAGE

TBD

TBD

DISPLAY BLANK
WHEN ARMED

DISPLAY ON AT
ALL TIMES

STATUS ALERTS
AFTER 2 HOURS

STATUS ALERTS
AFTER 8 HOURS

OUTPUTS
NORM. CLOSED

OUTPUTS
NORMALLY OPEN

ONE OF THE
OTHER DELAYS

ENTRY DELAY
0 SECONDS

ENTRY DELAY
20 SECONDS

ONE OF THE
OTHER DELAYS

Fn #

MEMORY LIGHT

OFF

MEMORY LIGHT

ON

ONE OF THE
OTHER DELAYS

ENTRY DELAY
40 SECONDS

ONE OF THE
OTHER DELAYS

ENTRY DELAY
60 SECONDS

EXIT DELAY
0 SECONDS

ONE OF THE
OTHER DELAYS

EXIT DELAY
20 SECONDS

EXIT DELAY
40 SECONDS

EXIT DELAY
60 SECONDS

ONE OF THE
OTHER DELAYS

ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS

SET EXIT AND ENTRY DELAYS A LITTLE LONGER
THAN THE CONTROL PANEL'S DELAYS

FUNCTION

FUNCTION

OPTION

FOLLOW THE TABLE AND USE THE [MEMORY] BUTTON
AND MEMORY LIGHT TO SELECT FUNCTION OPTIONS

FACTORY DEFAULT SETTINGS







OR

WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
UNTIL THE DESIRED RECEIVER CHANNEL NUMBER
FOR THE MULTI-BUTTON TRANSMITTER IS DISPLAYED

RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (1 SHOWN)

PRESS [ADVANCE] UNTIL THE DESIRED OUTPUT
ZONE NUMBER (1-8) FOR A TRANSMITTER BUTTON
IS DISPLAYED

RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (5 SHOWN)

CHANNEL

ZONE

CHANNEL

ZONE

MEMORY LIGHT WILL GO ON, SHOWING THAT THE
BUTTON WAS PROGRAMMED

PRESS [MEMORY]

MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ACCEPT THE TRANSMITTER
BUTTON

PRESS THE DESIRED TRANSMITTER BUTTON (TO
CREATE A DOUBLE-BUTTON LOCKOUT TRANSMITTER,
PRESS TWO BUTTONS AT THE SAME TIME)

REPEAT ZONE SELECTION TO PROGRAM ADDITIONAL
BUTTONS ON THE TRANSMITTER

NOTE: EACH MULTI-BUTTON TRANSMITTER USES ONE RECEIVER
CHANNEL AND A DIFFERENT OUTPUT ZONE FOR EACH BUTTTON

MEMORY LIGHT WILL BE OFF IF THE RECEIVER
CHANNEL IS VACANT (ONLY A VACANT RECEIVER
CHANNEL CAN ACCEPT A TRANSMITTER)

OR

RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (5 SHOWN)
(THE FIRST ZONE NUMBER ENTERED FOR THE
MULTI-BUTTON TRANSMITTER IS DISPLAYED)

MEMORY LIGHT WILL BE ON, SHOWING THAT THE
RECEIVER CHANNEL IS OCCUPIED WITH A
TRANSMITTER BUTTON LINKED TO THAT ZONE

PRESS [MEMORY]

MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ERASE THE TRANSMITTER
BUTTON FROM THE RECEIVER'S CHANNEL AND ZONE

PRESS [MEMORY] AGAIN

MEMORY LIGHT WILL GO OFF, SHOWING THAT THE
TRANSMITTER BUTTON HAS BEEN ERASED

WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH
THE MULTI-BUTTON TRANSMITTER TO ERASE

CHANNEL

ZONE

PRESS [ADVANCE] UNITL THE NEXT ZONE NUMBER
USED WITH THE SAME MULTI-BUTTON TRANSMITTER
IS DISPLAYED

CHANNEL

ZONE

RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (6 SHOWN)

REPEAT TO ERASE ANY ADDITIONAL BUTTONS THAT
WERE ENTERED FOR THAT TRANSMITTER

OR

RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (8 SHOWN)
(FOR MULTI-BUTTON TRANSMITTERS, THE FIRST ZONE
NUMBER ENTERED IS DISPLAYED)

PRESS [ADVANCE] UNTIL THE DESIRED OPTION
LETTER (A-d) IS DISPLAYED
(LETTERS ARE DISPLAYED BETWEEN "8" AND "1")

FOLLOW THE TABLE BELOW AND USE THE [MEMORY]
BUTTON AND MEMORY LIGHT TO SELECT OPTIONS

CONFIGURATION OPTION DISPLAYED
(CHANNEL 64, OPTION "b" SHOWN)

OPTION

MEMORY LIGHT

OFF

MEMORY LIGHT

ON

AUTO-RESTORE TX
(PIR & PORTABLES)

SELF-RESTORE TX
(DOORS & WINDOWS)

NO TX STATUS
REPORTS

TX MAKES STATUS
REPORTS

TX USES ENTRY &
EXIT DELAYS

TRANSMITTER
IS INSTANT

UNARMED ALARM
MEMORY FOR TX

ALARM MEMORY
ONLY WHEN ARMED

CHANNEL

ZONE

CHANNEL

OPTION

WITH THE PANEL DISARMED, PRESS [UP] OR
[DOWN] UNTIL THE DESIRED RECEIVER
CHANNEL NUMBER IS DISPLAYED

FACTORY DEFAULT SETTINGS




OR

WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")

"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)

PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS
THE OPTION "0"

PRESS [MEMORY]

RECEIVER OPTION "FUNCTION 0"

FUNCTION

FUNCTION

OPTION

DISPLAY SHOWS TOTAL NUMBER OF TRANSMITTERS
IN MEMORY FOR 10 SECONDS

# OF TXS

NOTE:

PRESSING [UP] AND [DOWN] TOGETHER ANYTIME

DURING PROGRAMMING WILL CAUSE THE SXR-64A TO

EXIT PROGRAM MODE AND RETURN TO RUN MODE

OR

WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")

"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)

PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS
THE OPTION "E"

PRESS AND RELEASE [MEMORY] THEN WAIT 5 SECONDS

RECEIVER OPTION "FUNCTION E"

FUNCTION

DISPLAY SCROLLS THROUGH EACH CHANNEL AND
LINKED ZONE. VERIFY THAT EACH CHANNEL IS LINKED
TO THE CORRECT ZONE. (THE FIRST ZONE NUMBER
ENTERED FOR A MULTI-BUTTON TRANSMITTER IS
DISPLAYED)

CHANNEL

ZONE

FUNCTION

OPTION

ACTIVATE EACH TRANSMITTER. WHEN THE RECEIVER
DECODES THE TRANSMITTER, IT WILL BE REMOVED
FROM THE DISPLAY. CONTINUE TESTING UNTIL NO
TRANSMITTERS REMAIN ON THE DISPLAY. PRESS
THE [MEMORY] BUTTON OR WAIT 10 MINUTES TO END
THE TEST.

WITH THE PANEL DISARMED, OPEN A PROTECTED
DOOR OR WINDOW

THE CHANNEL NUMBER AND "O" SHOULD BE
DISPLAYED (CHANNEL 64, OPEN CONDITION SHOWN)

CLOSE THE PROTECTED DOOR OR WINDOW

ARM THE CONTROL PANEL THEN OPEN A PROTECTED
DOOR OR WINDOW (AFTER ANY DELAYS)

THE "O" SHOULD DISAPPEAR WHEN THE TRANSMITTER
RESTORES. DASHES WILL SHOW IF ALL PORTALS
ARE CLOSED.

DISPLAY SHOULD SHOW AN "F" CONDITION FOR THE
FIRST ALARM IN

OPEN ADDITIONAL PROTECTED PORTALS. DISPLAY
SHOULD SHOW AN "A" FOR EACH ADDITIONAL ALARM
SIGNAL SENT. ALARM MEMORY WILL CLEAR WHEN
THE CONTROL PANEL IS DISARMED AND REARMED.

TRANSMITTER

CONDITION

TRANSMITTER

CONDITION

TRANSMITTER

CONDITION

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8

LB

STS COM TMP TST

ARM

SXR-64A TERMINALS

MOOSE Z1100

ZN1

1

COM

2

ZN2

3

ZN3

4

COM

5

ZN4

6

ZN5

7

COM

8

ZN6

9

AUX

POWER

2.2K EOL

RESISTORS

(ZONES PROGRAMMED

NORMALLY CLOSED)

(PROGRAMMED FOR

VOLTAGE WHEN ARMED)

ZN7

10

COM

11

ZN8

12

J16

8

28

29

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8

LB

STS COM TMP TST

ARM

SXR-64A TERMINALS

CADDX RANGER 9000

ZN1

1

COM

2

ZN2

3

ZN3

4

COM

5

ZN4

6

ZN5

7

COM

8

ZN6

9

AUX

POWER

3.3K EOL

RESISTORS

(ZONES PROGRAMMED

NORMALLY CLOSED)

AUX
OUT

(PROGRAMMED FOR

GROUND WHEN ARMED)

1 2 3 4

ZN7

10

COM

11

ZN8

12

ZN9

15

ZN10

17

COM

16

ZN11

18

14

13

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8

LB

STS COM TMP TST

ARM

SXR-64A TERMINALS

C&K 236

Z1

C

Z2

Z3

C

Z4

Z5

C

Z6

AUX

POWER

2.2K EOL

RESISTORS

(ZONES PROGRAMMED

NORMALLY CLOSED)

(PROGRAMMED FOR

VOLTAGE WHEN ARMED)

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8

LB

STS COM TMP TST

ARM

SXR-64A TERMINALS

NAPCO MA1000e

ZN1

15

COM

14

ZN2

16

ZN3

17

ZN4

19

ZN5

20

COM

18

ZN6

21

AUX

POWER

2.2K EOL

RESISTORS

(ZONES PROGRAMMED

NORMALLY CLOSED)

(PROGRAMMED FOR

GROUND WHEN ARMED)

5

6

NOTE: THIS PANEL DOES NOT
SUPPLY AN ARMED SIGNAL.
USE A PUSHBUTTON TO
RESET THE ALARM MEMORY
WHEN THE PANEL IS ARMED.
SET SXR-64A DELAYS TO "0"

AUX

C

RESET

E3 PGM

Advertising