Lincoln Impinger Advantage Digital Series 1164-000-EA User Manual

Page 12

Advertising
background image

Impinger II – Advantage Digital Service Manual - International

12

should be approx. 25-100 Hz. If these readings are not
achieved, replace conveyor motor. If the readings are
achieved, proceed.

Oven control

If the hall effect sensor readings are correct, but there
is no speed indicated on the display, replace the oven
control


TROUBLESHOOTING GUIDE

IMPINGER II ADVANTAGE

SERIAL NUMBER 2038616 AND ABOVE

(OVENS WITH PUSH BUTTON CONTROLS)

MODEL 1164-000-EA

400/230VAC

50HZ.

3

PHASE

REFER TO PROPER SCHEMATIC FOR IDENTIFIED COMPONENTS

SYMPTOM POSSIBLE

CAUSE

EVALUATION

Oven fan will not run

Incoming power supply

Check breaker, reset if required. Check power plug to
be sure it is firmly in receptacle. Measure incoming
power, call power co. if needed.

Oven cavity hi-limit
thermostat

Terminals are normally closed, opens at 660

°F (350°C).

If open, reset and test oven for proper operation. If
thermostat will not hold for maximum oven temperature,
and oven is not exceeding control setting, check for
proper location of capillary bulb ion its spring holder. If
above checks are okay, replace hi-limit thermostat.

Fuse, 10 amp

Check, replace if necessary.

Fuse holder

Check, replace if necessary.

Hi-limit thermostat, control
box

Check for voltage on both sides of switch. Terminals are
normally closed. If open, reset and test oven for proper
operation. If thermostat will not hold, and control box
temperature is not exceeding 140

°F (60°C), replace

thermostat.

Switch, main fan

With power off, check continuity between switch
terminals. Replace as needed.

Motor, main fan

Check for opens, shorts or grounds. With power off, turn
fan blade to check for locked rotor.

Capacitor

Check for shorts or grounds.
WARNING: Capacitor has a stored charge, discharge
before testing.

No control box cooling

Incoming power supply

Check breaker, reset if required. Check power plug to
be sure it is firmly in receptacle. Measure incoming
power, call power co. if needed.

Oven cavity hi-limit
thermostat

Terminals are normally closed, opens at 660

°F (350°C).

If open, reset and test oven for proper operation. If
thermostat will not hold for maximum oven temperature,
and oven is not exceeding control setting, check for
proper location of capillary bulb in its spring holder. If
above checks are okay, replace hi-limit thermostat.

Fuse, 10 amp

Check, replace if necessary.

Fuse holder

Check, replace if necessary.

Hi-limit thermostat, control
box

Check for voltage on both sides of switch. Terminals are
normally closed. If open, reset and test oven for proper
operation. If thermostat will not hold, and control box
temperature is not exceeding 140

°F (60°C), replace

thermostat.

Switch, main fan

With power off, check continuity between switch

Advertising