16

D. Unplug

thermocouple.

E. Unplug 2 motor connectors.
F. Remove 8 bolts from oven back ( 4 left, 4 right ) and lift out.
G. Remove 1 screw from fan hub and slide fan blade off of motor shaft. ( note location of fan blade

for reinstallation )

H. Loosen locknuts on cone. Remove 2 mounting bolts and remove motor from back assembly.
I.

Remove 4 hex head screws from motor mount bracket. Remove motor mount from motor and
reinstall on new motor.

J. Reassemble in reverse order. NOTE: 1. Make sure motor is centered in back housing.

2. Verify correct location of fan blade and that it is not hitting fan shroud.

3. Make sure all connectors are properly seated and making good contact.

4. When reinstalling gas manifold across back of oven, check all fittings for leaks.

K. Check system operation (allow 30 minute preheat for all checks) NOTE: Position of the fan on

the motor shaft will be 1.875” from the top of the oven back cone to the blade spider assembly
on the fan hub. (see drawing below ).


THERMOCOUPLE (TYPE K) – REPLACEMENT

A. Remove control box covers. Remove motor cover and remove oven back to access

thermocouple.

NOTE: Removal of oven back assy. Is required to replace thermocouples.

B. Remove thermocouple from wire form in oven chamber and remove from chamber.

NOTE: R. H. thermocouple (viewed from front) is connected directly to the temperature control
board, remove 2 wires , make note of wire colors and location. When changing L. H.
thermocouple (viewed from front, the back motor cover must also be removed to gain access to
the thermocouple connector plug.)

C. Reassemble in reverse order making sure bulb is placed securely in the wire form in the oven

chamber.

D. Check system operation, recalibrate as needed. NOTE: The R. H. and L. H. thermocouples have

different connectors on the wire ends and must be ordered accordingly.

THERMOCOUPLE MEASUREMENT

TEMPERATURE (

°F) D.C.

MILLIVOLTS

200

°

2.8

250

°

4.0

300

°

5.1

350

°

6.0

400

°

7.1

450

°

8.2

500

°

9.3

550

°

10.4

600

°

11.5


BEARING, CONVEYOR – REPLACEMENT

A. Remove conveyor from oven and place on a flat work surface.
B. Remove connecting links from conveyor belting. See Installation and Operating Instructions

Manual.

C. Remove conveyor belting from conveyor. Remove drive sprocket from drive shaft.
D. Move drive shaft or idle shaft toward end of conveyor, and shaft with bearings will now slip out of

holding bracket.

E. Replace bearing and reassemble in reverse order.

CONTROL TRANSFORMER – REPLACEMENT
A. Shut off power at main breaker.
B. Remove wires from primary side, note color and location.
C. Remove wires from secondary side, note color and location.
D. Remove two mounting screws and remove transformer.
E. Reassemble in reverse order and check system operation.

Advertising