PUMP-Rec-12 Rev B

PUMP

Recommendation

PUMP RECOMMENDATION FOR

INTELLI-FIN 1500-2000 WATER HEATER

Pump Specifications

Part No.

HorsePower

Flanges

Valute Material

Flange Material

Vendor

Vendor Product Series

Orientation

ARM3072PAB 3/4 2-1/2" Bronze

Bronze

Armstrong

2B1060

Vertical


Installation Specifications

Recommended for

Based on

Pump

Model Numbers

Maximum GPM

Installation Type

Intelli-fin Wtr Htr, IW(N,L) 1500-2000

90 GPM

Single Water Heater piped to a Single Storage Tank

ARM3072PAB

Based on

Based on

Minimum Pipe Diameter

Connecting piping

2-1/2"

Maximum 45 feet straight pipe with 6-Elbows, 2-Unions, 2-Ball Valves and 1-Cold Water Inlet Tee

IMPORTANT: Read the Intelli-fin 1500-2000 Installation and Operation Manual. If the planned system exceeds
the pump capacity in flow and/or head see “Pump Curves-All Pumps” for alternate pumps and pump curves.

OIL PORT

A

C

16”

19-1/2”



(See ¾ HP Curve)











B

D

11-1/2”







1