2.5 Connecting the LFH Hub

Use the following procedures to connect 100BASE-TX network devices
to the hub:

NOTE:

If the Uplink Port is being utilized on the LFH hub, the adja-

cent Port may not be used. Conversely, if that Port is being utilized, the
Uplink Port may not be connected.

The following table describes the two cable types:

Make sure that the length of the straight-through cable between the
LFH hub and the other device does not exceed 100 meters, including all
patch cables and cross-connect wires.

Make sure that the length of the straight-through cable between two
hubs does not exceed 5 meters.

9

LFH4-M

Ports 1-4

Uplink Port

LFH8-M

Ports 1-8

PC, Workstation

S

C

Server

S

C

Hub, Switch port

C

S

Hub, Switch uplink port

S

C

S = Straight Cable C = Crossover cable

Straight cable

Crossover cable

Pin 1

TD+

RD+

Pin 2

TD-

RD-

Pin 3

RD+

TD+

Pin 6

RD-

TD-