Lucent Technologies VPN Firewall Brick 20 User Manual

Page 3

Advertising
background image

3

VPN Firewall Brick

®

20 platform – Back Panel

13.VPN

Maximum number of dedicated VPN tunnels – 55
Manual Key, IKE, PKI (X.509)
3DES (168-bit), DES (56-bit)
SHA-1 and MD5 authentication/integrity
Replay attack protection
Remote access VPN
Site-to-site VPN
IPSec NAT Traversal (UDP encapsulated IPSec)
LZS compression
Spliced and nested tunneling

14.VPN Authentication

Local passwords, RADIUS, SecurID, X.509 digital
certificates with Entrust CA
PKI Certificate requests (PKCS 12)
Automatic LDAP certificate retrieval

15.High Availability

VPN Firewall Brick

®

platform to VPN Firewall Brick

®

platform active/passive failover with full synchronization
400 millisecond device failure detection and activation
Session protection for firewall and VPN
Link failure detection
Alarm notification on failover
Encryption and authentication of session
synchronization traffic
Self-healing synchronization links
Lucent Proxy Agent load sharing supports high
availability for content security services

16.Diagnostic Tools

Out of band debugging and analysis via serial
port/modem/terminal server
Centralized, secure remote console to any VPN Firewall Brick

®

unit supporting Ping, Traceroute, packet trace with filters
Remote VPN Firewall Brick

®

platform bootstrapping

Real-time log viewer analysis tool

17.3-Tier Management Architecture

Centralized, carrier-class, active/active management
architecture with Lucent Security Management Server
(LSMS) software
Secure VPN Firewall Brick

®

platform to LSMS

communications with Diffie-Helman and 3DES encryption,
SHA-1 authentication and integrity and digital certificates
for VPN Firewall Brick

®

platform/LSMS authentication

Up to 100 simultaneous administrators securely managing
all aspects of up to 1000 VPN Firewall Brick

®

units

Secure, reliable, redundant real-time alarms, logs, reports

18.Certifications

ICSA V3.0A Firewall Certified, ICSA V1.0B IPSec Certified
National Security Agency EAL2 Government Protection Profile
Certified, EAL4 in progress

19.Mean Time Between Failure

127,000 Hrs.

20.Dimensions (W x L x H)

6.2” x 8.6” x 1.3” 16 cm x 22 cm x 3 cm

21.Cooling

Passive heatsink

22.Operating Altitude

Up to 13,123 ft (4,000 m)

23. Environmental

Operating
Temperature: 0 to 40º C
Shock: 2.5g at 15 – 20 ms on any axis
Relative Humidity: 5–95%
Vibration: 5g at 2 – 200Hz on any axis
Non-Operating
Temperature: 0 to 70º C
Shock: 35g at 15 – 20 ms on any axis
Relative Humidity: 5–95%
Vibration: 5g at 2 – 200Hz on any axis

24.Power

External AC to DC Power Supply: rated 25W Max
Switching mode, 100–240V AC, 50–60Hz
Consumption: 0.19A typical at 115VAC

25.Safety Listings

USA – UL

®

1950

Canada – CSA 22.2 No. 950
EU – EN/IEC 60950
Japan – CB Scheme IEC 60950

26.EMC Certifications

USA – FCC Part 15, Class B
Canada – IC-ES003
EU – EMC Directive
Japan – VCCI

Advertising