Paralyte 2424, Options & accessories, Specifications – Lightolier Paralyte 2424 PLA2G16LS26U User Manual

Page 2: Specifications (continued), Photometry, Ordering information, Job information type, Lightolier

Advertising
background image

Paralyte 2424

PLA2G16LS26U

Page 2 of 2

2' x 2' Recessed Fluorescent, 3-1/8" Deep, 16 Cell Parabolic Louver

Static and Air Return 2 Lamp, T8 or T12

Lightolier

a Genlyte Thomas Company

www.lightolier.com

Technical Information: (978) 657-7600 • Fax (978) 658-0595
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division)
A0902

Section 2/Folio G50-53 Rev. A

Job Information

Type:

Options & Accessories

Prewiring: 3/8” factory prewired cable (three no. 18 AWG leads, 6’ long),
Suffix: FF6, (Four no. 18 AWG leads, 6’ long), Suffix: FF14.
Fusing: Internal fast-blow fusing. Suffix: GLR.

Internal slow-blow fusing. Suffix: GMF.

Fluorescent Emergency Lighting System: Factory-installed emergency power
battery pack with charger and inverter, concealed in fixture channel. Operates one
fluorescent lamp at reduced light output for 90 minutes. Suffix: EM.
Radio Interference Filter: 120 or 277 volt, 50 or 60 Hz.
One per fixture. Suffix: R. One per ballast. Suffix: B.
Electrical Options: Special wiring, fusing or dimming ballasts and installed
lamps are available, consult your Lightolier representative or factory.
T-Bar Spacer: If T-bar is less than 1-1/2” deep, order Catalog Number: STC.
2 each end is required.

Specifications

Performance: In an installation of 2 lamp 31W Iuminaires in a room cavity ratio
of 1, with reflectance of 80% ceiling, 50% wall, 20% floor, the C.U shall not be
less than 64. To prevent glare the VCP shall not be less than 88 either lengthwise
or crosswise (at 100fc level) and the average brightness at 65° shall not exceed
206 foot-Iamberts. To control veiling reflections, luminaire output in the 3C°-90°
zone shall not be less than 68.6%.

Specifications (continued)

Air Return: Designed to provide optimum air return. Air is returned through the
lamp compartment for all ceiling systems and direct to plenum through slots in
slot grid and narrow grid ceiling systems.
Materials: Chassis parts are die-formed code gauge cold rolled steel. Housing
is embossed for rigidity with all edges turned up for safe handling. Louver is
pre-anodized aluminum (Coilzak

®

or equal).

Finish: Louver–semi-specular anodized low iridescence, vertical grain reflector
sheet. Cavity–white baked polyester minimum 86% reflectance. Phosphate
undercoating. Chassis exterior–black baked polyester enamel.
Electrical: Thermally protected class “P” ballast C.B.M. approved, non PCB. If
K.O. is within 3” of ballast, use wire suitable for at least 90°.
Labels: I.B.E.W./UL and ULc Listed.

Photometry

Model No. PLA2G16LS26U120SO

PL

Paralyte

2424:

3-1/8" Deep

Parabolic
Precision

Contoured Pre-

anodized

Aluminum

Louver

A

Body Style:

A= Air Handling

/Static

2

Fixture

Width

G

Ceiling Type:

G=Grid (lay-in T-bar)

16

Number of

Cells

Louver Finish:

L = Low

Iridescence

Semi-specular
(standard)

W = White Paint

S

Ballast Cover:

S=Single V Reflector

2

Lamp

Quantity

6U

Lamp/

Fixture Length:

6" U Lamp

T8 or T12

(Nominal 24")

Voltage:

120 or 277

Options:

Add appropriate
suffix to catalog

no, ie: (GLR)

Ballast Type:

1–2 Lamp Mag. T12

LE

*

<

20THD

<

10THD

1–2 Lamp Elec. T8

SO*

H

I

*

LOL T8 Dimming

PS

*

*Instant Start Standard

Other dimming options. Consult factory.

coefficients of utilization — zonal cavity method (effective floor cavity reflectance 0.20)

RF

20

20

20

RC

80

50

30

RW

70

50

30

50

30

10

50

30

10

1

66

64

62

60

59

58

58

57

56

2

62

58

55

55

52

50

53

51

49

3

57

52

48

50

46

44

48

45

43

4

53

47

42

45

41

38

43

40

38

5

48

42

37

40

36

33

39

35

33

6

45

37

33

36

32

29

35

31

29

7

41

34

29

32

28

25

31

28

25

8

38

30

25

29

25

22

28

24

21

9

34

27

22

26

22

19

25

21

18

10

32

24

20

23

19

16

23

19

16

visual comfort probability (rated lumens per lamp 3150.)

room size

ceiling height

ceiling height

W

L

8.5

10.0

13.0

16.0

8.5

10.0

13.0

16.0

20

20

81

75

71

80

79

69

60

71

20

30

84

78

74

73

82

73

66

65

20

40

86

80

77

75

82

75

70

69

20

60

87

81

80

78

83

75

73

72

30

20

85

79

71

76

83

75

64

70

30

30

87

82

74

70

86

78

68

65

30

40

88

83

77

72

86

79

72

68

30

60

89

84

80

75

86

79

75

72

30

80

89

85

81

78

86

79

74

72

40

20

86

82

75

75

84

77

69

71

40

30

88

83

77

70

87

80

73

67

40

40

89

85

80

73

87

81

76

70

40

60

90

86

82

75

87

81

77

73

40

80

90

86

83

78

87

81

77

73

40

100

91

86

83

78

87

81

77

73

60

30

88

84

79

73

87

81

75

70

60

40

89

86

82

75

88

82

78

73

60

60

90

87

83

77

88

82

79

75

60

80

91

87

84

79

88

83

79

75

60

100

91

87

85

80

88

83

79

75

100

40

89

86

82

77

88

82

79

74

100

60

90

87

84

79

88

82

81

77

100

80

91

87

85

81

88

83

81

78

100

100

91

88

86

82

88

83

81

78

room cavity ratio

luminaries lengthwise

luminaries crosswise

LER = FP - 49.5 IW - 58.0 BF - 0.87
Comparative yearly lighting energy cost per 1000 lumens = $4.85

ITL34139
LIGHTOLIER
PLA2G16LS26U120SO

Ordering Information

Explanation of Catalog Number. Example: PLA2G16LS26U120SOGLR

Advertising