Lopi Clean Face Gas Fireplace User Manual

Constitution, Clean face gas fireplace, Gas input & performance

Advertising
background image

Gas Input & Performance:

• Adjustable High Heat System:

20,800 – 38,000 Btu's (NG)

23,500 – 38,000 Btu's (LP)

• Heater Rated Fireplace: Heats up to 1,000 sq. ft.*

*Heating capacity will vary depending on the temperature zone
you live in.

Framing Dimensions:

See Installation Manual or visit www.lopistoves.com under Constitution

1. Hearth Requirements: Extends 10” from face and 49 1/2”

2.

wide when installed flush. Not required when raised 6”

2.

(See Installation Manual or www.lopistoves.com for details)

2. Non-combustible facing - Two side and two top pieces provided

4.

with fireplace.

3. Side Wall Clearance: 11”

4. Mantle Clearances: 50” from base of fireplace.

4.

Maximum allowed mantle depth: 12”

5. Minimum fireplace enclosure height 60”.

6.

Measured from base of fireplace.

6. Minimum framing:

6.

50” wide x 56 3/4” tall x 25” deep.

7. Facing Requirements:

6.

Provided fiber board or other non-combustible

6.

material must extend from the base of the fireplace to

6 .

the header and to the framing members on both sides

Features:

• No grills for a traditional masonry fireplace look.

• Durable, tempered glass with safety screen.

Screen is removable.

• Fire viewing area 1080 sq. in.

• Realistic, four-piece detailed log set with embers and twigs.

• Digital Home Comfort Control System can be operated by

the hand-held remote control and the wireless wall control.

Operate Your Fireplace Green

- The Electronic Gas Valve can

be run for greater efficiency in the “Intermittent Pilot Mode”

with the gas pilot turned off until you need it or “Standing

Pilot Mode”,with the gas pilot always on, for reliable cold

weather operation.

• Natural (NG) or Propane (LP) operation.

• Uses Simpson Duravent 8 5/8” x 6” chimney.

• Seven Year “Real World” Warranty.

Tested and Certified by OMNI-Test Laboratories Inc. to ANSI Z21.88b
“Vented Gas-Fired Direct Fireplace Heater”.

Must be installed in accordance with all local codes, if any:if not, follow ANSI Z223.1
and the requirements listed in the Owner’s Manual.

Note: Improper installation of your gas appliance or failure to operate it in accordance to the guidelines detailed in the Owner’s Manual may
negate your warranty. We recommend all Lopi appliances be installed and maintained on an annual basis by your specialty hearth retailer.

4

1

1

2

6

5

1” to 1

-1/2

” Thick Cement Board

4

3

10

” Min.

25

” Min.

Maintain

a 14” min. width

between studs

and max. 3 1/2”

depth of studs

for chimney

clearance.

41 1/2”

7

Constitution

tm

Clean Face Gas Fireplace

Constitution

tm

Clean Face Gas Fireplace

We reserve the right to improve or change our products without prior notification. Consult the Owner’s Manual for complete installation requirements. Photos and illustrations are for descriptive purposes only.

Your Lopi Authorized Dealer is Located At:

Visit us online at: www.lopifire.com

© Copyright T. I. 10/2007 Printed in U.S.A.

#98800000

Advertising