7

Note: The framed depth, 28

¹⁄₈" (714 mm) from

a framed wall, must always be measured from
a finished surface. If a wall covering such as
drywall is to be attached to the rear wall, then
the framed depth must be measured from the
drywall surface. It is important that this dimen-
sion be exact.

If the appliance is to be elevated above floor
level, a solid continuous platform must be
constructed.

The header may rest on the top metal spacers,
but must not be notched to fit around them.

Consult all local codes.

FRAMING SPECIFICATIONS

Figure 11

Header

Fireplace Framing

B

A

False
Header

H

Figure 12

Framing Dimensions for Ceiling

Flue Type

A

B

FTF10 Vertical

19"

19"

(483 mm)

(483 mm)

FTF10

19"

29"

Offset 30

°

(483 mm)

(737 mm)

Figure 13

A

Outside Chase

G

C

J

Back Wall of Chase/Enclosure

Including Finising Materials

if any

Rough

Framing Face

(Unfinished Shown)

FOAK

Combustion

Air Kit - Optional

Framing Dimensions for Roof

Pitch

C

D*

0/12

19"

19"

(483 mm)

(483 mm)

6/12

19"

22"

(483 mm)

(559 mm)

12/12

19"

27"

(483 mm)

(686 mm)

* Perpendicular to roof ridge

Figure 15

Figure 16

Figure 14

A

B

Ceiling Framing

C

D

Roof Framing

Corner Installation

K

D

A

E

F

Back Wall of

Chase/Enclosure

Including Finising

Materials

if any

Rough
Framing Face
(Unfinished Shown)

FOAK Combustion

Air Kit - Optional

Framing Dimensions

Model LA41

A

50

¹⁄₂"

1283 mm

B

53"

1346 mm

C

34

⁵⁄₁₆"

873 mm

D

19

¹⁄₈"

486 mm

E

90

¹⁄₄"

2292 mm

F

45

¹⁄₈"

1146 mm

G

28

¹⁄₈"

714 mm

H

48

³⁄₈"

1228 mm

J

26

¹⁄₈"

664 mm

K

63

¹¹⁄₁₆" 1622 mm

Note: All framing dimensions calculated for 1/2"
dry wall at the fireplace face. If sheathing the
chase or finishing with other thickness materials,
calculations will need to be made. False header
should be constructed of 2 x material only.

A