4x4pl, Calculite, Matrix – Lightolier 4X4PL User Manual

Page 2: Lensed downlight, 32w triple tube, specular clear reflector trim, 26w triple tube, specular clear reflector trim, Job information type, One sylvania lamp, 2400 lumens, One philips lamp, 1800 lumens

Advertising
background image

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • A0409

Calculite

®

Matrix

®

Lensed Downlight

4X4PL

Page 2 of 2

4 1/2" X 4 1/2" Square Aperture (1) 26/32W Triple Tube Prismatic Lens

Job Information

Type:

1 .49 .48 .47 .48 .47 .46 .46 .45 .44 .44 .44 .43 .43 .42 .42 .41

2 .45 .44 .42 .45 .43 .42 .43 .42 .41 .42 .41 .40 .41 .40 .39 .38

3 .42 .40 .39 .42 .40 .38 .41 .39 .38 .40 .38 .37 .39 .37 .36 .36

4 .40 .37 .35 .39 .37 .35 .38 .36 .35 .37 .36 .34 .36 .35 .34 .33

5 .37 .34 .32 .36 .34 .32 .36 .34 .32 .35 .33 .32 .34 .33 .31 .31

6 .34 .32 .30 .34 .32 .30 .33 .31 .30 .33 .31 .29 .32 .31 .29 .29

7 .32 .29 .28 .32 .29 .27 .31 .29 .27 .31 .28 .27 .30 .28 .27 .26

8 .30 .27 .25 .29 .27 .25 .29 .27 .25 .29 .26 .25 .28 .26 .25 .24

9 .28 .25 .23 .27 .25 .23 .27 .25 .23 .27 .24 .23 .26 .24 .23 .22

10 .26 .23 .21 .25 .23 .21 .25 .23 .21 .25 .22 .21 .24 .22 .21 .20

32W Triple Tube, Specular Clear Reflector Trim

One Sylvania lamp, 2400 lumens

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens

% Lamp

% Luminaire

0-30

575

23.97

54.78

0-40

840

35.02

80.02

0-60

1049

43.73

99.91

0-90

1050

43.77

100.00

0

781

781

781 781

781

5

777

778

781 784

785

74

10

755

760

776 789

794

15

706

720

757 786

792

212

20

635

657

716 757

760

25

550

575

642 684

688

289

30

459

485

544 578

591

35

363

386

421 460

489

265

40

267

280

291 344

375

45

190

191

185 231

258

165

50

127

119

109 140

163

55

16

28

42

40

19

44

60

2

2

7

2

2

65

0

0

0

0

0

1

70

0

0

0

0

0

75

0

0

0

0

0

0

80

0

0

0

0

0

85

0

0

0

0

0

0

90

0

0

0

0

0

Test Report

1711FR

Mar. 24, 2002

Angle Along

22.5

45 67.5 Across Lumens

CANDLEPOWER SUMMARY

EFFICIENCY = 43.8% Spacing Criterion: Along = 1.0 Across = 1.1

% Effective Ceiling Cavity Reflectance

1 .53 .52 .51 .52 .51 .50 .50 .49 .48 .48 .47 .47 .46 .46 .45 .45

2 .49 .48 .46 .48 .47 .45 .47 .46 .44 .46 .44 .43 .44 .43 .43 .42

3 .46 .44 .42 .45 .43 .42 .44 .42 .41 .43 .42 .40 .42 .41 .40 .39

4 .43 .41 .39 .43 .40 .38 .41 .39 .38 .41 .39 .37 .40 .38 .37 .36

5 .40 .37 .35 .40 .37 .35 .39 .37 .35 .38 .36 .35 .37 .36 .34 .34

6 .38 .35 .33 .37 .34 .33 .36 .34 .32 .36 .34 .32 .35 .33 .32 .31

7 .35 .32 .30 .35 .32 .30 .34 .31 .30 .33 .31 .29 .33 .31 .29 .29

8 .32 .30 .28 .32 .29 .27 .32 .29 .27 .31 .29 .27 .31 .29 .27 .26

9 .30 .27 .25 .30 .27 .25 .29 .27 .25 .29 .27 .25 .29 .26 .25 .24

10 .28 .25 .23 .28 .25 .23 .27 .25 .23 .27 .25 .23 .27 .25 .23 .22

ROOM CA

VITY RA

TIO

cu

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

80

70

50

30

10

0

26W Triple Tube, Specular Clear Reflector Trim

One Philips lamp, 1800 lumens

ZONAL LUMENS AND PERCENTAGES

Zone

Lumens

% Lamp

% Luminaire

0-30

475

26.42

55.71

0-40

689

38.32

80.79

0-60

852

47.38

99.90

0-90

853

47.43

100.00

0

646

646

646 646

646

5

644

645

647 648

649

62

10

625

631

642 651

653

15

583

596

628 646

647

175

20

517

543

591 624

628

25

445

470

531 575

583

239

30

368

392

450 492

500

35

287

303

344 375

389

214

40

209

217

232 267

287

45

152

148

145 178

199

129

50

104

94

87 106

125

55

12

26

33 29

16

35

60

1

1

5

1

2

65

1

0

0

1

1

1

70

0

0

0

0

0

75

0

0

0

0

0

0

80

0

0

0

0

0

85

0

0

0

0

0

0

90

0

0

0

0

0

Test Report

1764FR

Apr. 5, 2002

Angle Along 22.5

45 67.5 Across Lumens

CANDLEPOWER SUMMARY

EFFICIENCY = 47.4% Spacing Criterion: Along = 1.0 Across = 1.2

% Effective Ceiling Cavity Reflectance

ROOM CA

VITY RA

TIO

cu

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

80

70

50

30

10

0

20% Floor Cavity Reflectance

20% Floor Cavity Reflectance

Based on specular clear (CL) finish. To estimate other finishes, multiply candelas
and CU values by 0.95 for CCL, by 0.90 for CCD.

Advertising