4r28, Architectural decorative, Features – Lightolier Architectural Decorative 4R28 User Manual

Page 2: Lamping (by others), Electrical, Mounting, Labels, Application data, Job information type

Advertising
background image

Job Information

Type:

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2009 Philips Group • D0609

Architectural Decorative

4R28

Page 2 of 2

Pendalux Traditional 28" Diameter Body 4-26/32/42 Triple Tube

Features

1. Diffusing Reflector: White translucent acrylic, 3/16” thick.
2. Inner Dirt Shield: White translucent acrylic, 1/8” thick.
3. Chassis: Steel 20 gauge, semi-gloss white powder-coat finish.
4. Suspension: Swivel (central) stem, 5/8” steel tube. Canopy, steel, 7” Dia.

fastened internally, no exposed hardware. Permits installation on ceilings
with slope of up to 45°. Complies with California Code.

5. Rods: Reflector Bowl is suspended from a central point on three 3/16”

steel tubes.

6. Lampholder: Multi-wattage, 4-pin, will accept either GX24q-3 or GX24q-4

lamp base.

7. Flange Trim: Steel 20 gauge, Plated or Painted finish.

Lamping (by others)

Compact Fluorescent: Triple Tube, 26, 32, or 42 Watts.

General Electric

Osram/Sylvania

Philips

26W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

F26TBX/*/A/4

CF26DT/E/IN/*

PL-T26W/*/4P/ALTO

32W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

F32TBX/*/A/4P/EOL

CF32DT/E/IN/*

PL-T32W/*/4P/ALTO

42W Triple Tube 4-Pin

(Amalgam) Compact

Fluorescent Lamp

F42QBK/*/A/4P/EOL

CF42DT/E/IN/*

PL-T42W/*/4P/ALTO

*Manufacturers’ color temperature designation.

Electrical

Ballast: Electronic, 2-Lamp HPF, Class P, Programmed Start. Universal Voltage
120/277V, Multi-Wattage 26/32/42W.
4 Lamp

26 Watt

32Watt

42Watt

Voltage

120V 277V

120V 277V 120V 277V

Total Input Watts

112

110

138

134

182

180

Max. Line Current(amps)

0.92

0.40

1.16

0.52

1.52

0.64

Power Factor

>0.95 >0.95

>0.98 >0.98 >0.98 >0.98

Ballast Factor

1.02 1.02

1.00

1.00

0.98

0.98

THD<10% Minimum Starting Temperature: 0°F/-18°C

Mounting

Mounts directly to 4” outlet box, using crossbar hanger, supplied.

Labels

cULus Suitable for Damp Locations.

Application Data

28 Inch Diameter
30' x 30' x 10' Space
Luminaire

Spacing: 10’ x 10’

Susp. Dist. 28”

4 Lamps

26W

32W

42W

TTT

TTT

TTT

Illum. (FC) Maint.

26

33

45

Lum. Ratio

15/1

15/1

14/1

Watts/Sq. Ft.

1.10

1.36

1.86

Reflectancies: 80% Ceiling, 50% Walls, 20% Floor.
Light Loss Factor = .75 (.88 BF x .85)
FC (footcandles) at 30” work plane.

ANGLE MEAN CP LUMENS

0

309

5

311

30

10

307

15

301

85

20

293

25

283

131

30

269

35

252

158

40

233

45

215

166

50

195

55

172

154

60

148

65

124

123

70

101

75

76

82

80

56

85

37

45

90

35

CERTIFIED TEST REPORT NO. 4R28442A

COMPUTED BY LSI PROGRAM **TEST-LITE**

LIGHTOLIER INDIRECT/DIRECT PENDANT FIXTURE

CAT. #4R28442APBU, 28” DIFFUSER

4-42W T/E OSRAM LAMPS. LUMEN RATING = 3200 LMS.

2-ADVANCE BALLAST #ICF-2S42-M2-LD, 120 VAC

TESTED ACCORDING TO IES PROCEDURES. TEST DISTANCE EXCEEDS FIVE

TIMES THE GREATEST LUMINOUS OPENING OF LUMINAIRE.

ANGLE MEAN CP LUMENS

90

35

95

169

236

100

494

105

819

845

110

1064

115

1245

1234

120

1417

125

1585

1408

130

1692

135

1744

1349

140

1785

145

1825

1146

150

1863

155

1875

862

160

1838

165

1755

491

170

1587

175

1471

146

180

1584

C

ANDLEPOWER SUMMARY

DATE: MAR. 1, 2001

PREPARED FOR:

LIGHTOLIER, FALL RIVER, MA

COEFFICIENTS OF UTILIZATION ZONAL CAVITY METHOD

%EFFECTIVE FLOOR CAVITY REFLECTANCE = .20

80

70

50

30

10

50 30 10 50 30 10 50 30 10 50 30 10 50 30 10 0

1

.58 .55 .53 .50 .48 .46 .37 .35 .34 .24 .23 .22 .12 .12 .12 .08

2

.50 .46 .43 .44 .41 .38 .32 .30 .28 .21 .20 .19 .11 .10 .10 .07

3

.44 .40 .36 .39 .35 .32 .28 .26 .24 .18 .17 .16 .09 .09 .08 .06

4

.39 .34 .30 .34 .30 .27 .25 .22 .20 .16 .15 .13 .08 .08 .07 .05

5

.34 .29 .26 .30 .26 .23 .22 .19 .17 .15 .13 .12 .08 .07 .06 .04

6

.31 .26 .22 .27 .23 .19 .20 .17 .15 .13 .11 .10 .07 .06 .05 .04

7

.27 .22 .19 .24 .20 .17 .18 .15 .13 .12 .10 .09 .06 .05 .05 .03

8

.25 .20 .16 .22 .17 .15 .16 .13 .11 .11 .09 .07 .06 .05 .04 .03

9

.22 .17 .14 .20 .16 .13 .14 .12 .10 .10 .08 .07 .05 .04 .04 .02

10

.20 .16 .13 .18 .14 .11 .13 .10 .08 .09 .07 .06 .05 .04 .03 .02

DETERMINED IN ACCORDANCE WITH CURRENT IES PUBLISHED PROCEDURES

ZONAL LUMENS AND PERCENTAGES

ZONE

LUMENS

% LAMP

%LUMINAIRE

0-30

358

2.61

3.20

0-40

588

4.29

5.28

0-60

1046

7.80

9.59

0-90

1373

10.73

11.20

40-90

784

6.14

6.56

60-90

327

2.55

2.88

90-180

8040

62.81

88.80

0-180

9412

73.54

100.00

** EFFICIENCY = 73.5% **