Heritage dvl, Direct vent large gas stove, Ember-fyre burner – Lopi Heritage DVL Direct Vent Large Gas Stove User Manual

Page 2: Stove dimensions, Clearances to unprotected combustible walls, Your authorized dealer is

Advertising
background image

HERITAGE DVL

Direct Vent Large Gas Stove

TM

Your
Authorized
Dealer Is:

©Copyright 2002 T. I. Printed In U.S.A. Lopi reserves the right to alter or improve its products at any time without notification.

NOTE: Improper installation of your gas appliance or failure to operate it according to
the guidelines detailed in the Owner's Manual, may negate your warranty and endanger
your home and family. Contact local building or fire officials about restrictions and
installation requirements in your area.

SAFETY TESTING: DIRECT VENT tested by OMNI-Test Laboritories, Inc., to ANSI
Z21.88/CSA 2.33-1998, and applicable sections of UL 307b and CAN/CGA 2.17-M91 and
other requirements listed in the Owner’s Manual.

Visit our WEB site at: www.lopistoves.com

HEATING CAPACITY: May vary depending on the degree of home insulation, floor plan and the ambient temperature zone of the area in which you live.

Available with black door and black grill
and can be upgraded with the optional
24 karat plated gold door and gold
convection grill.

Large design - Ideal for home or multiple
room heating.

Approved for residential, mobile home
and bedroom applications.

Award winning Ember-Fyre Burner,
(patent pending) the most realistic fire.

Heater Rated.

Millivolt system allows the stove to operate
even during power outages.

30 second pilot drop-out switch for safety.

Heat output can be adjusted down
without the loss of the beautiful flame
and glowing embers.

Ships with NG burner installed, and includes
an easy-to-convert LP conversion kit.

Delicate cast molding detail on stove top
& pedestal base.

Standard 130 CFM convection blower.

Optional two-tone brick pattern fireback.

Optional wall switch, wall thermostat
and remote control thermostat.

Optional modulating remote control
thermostat that allows you to
simultaneously adjust the flame height
and convection blower speed.

Fuel

Steady State

Efficiency (NG)

Natural Gas (NG)

or

Propane (LP)

Heating

Capacity

Up to

2,000 sq. Ft.

Direct Vent

6 5/8"

DuraVent

Direct Vent

Standing Pilot

Generates Electricity to

Allow Operation Even

During Power Outages

(NG) 29,600 to 43,000 Btu's/Hr.

(LP) 26,000 to 43,000 Btu's/Hr.

Input

Adjustable

AFUE

71% (NG)

73.7% (LP)

83% NG - 86% LP

78% NG - 81% LP

Ember-Fyre

Burner

The breakthrough Ember-Fyre™ burner
(patent pending) features a level of
realism and efficiency so remarkable
that it is difficult to tell apart from
our real wood-fired stoves.

#1

Gas reaches the appliance,

through a high quality European
SIT gas valve.

#2

The SIT valve has a variable

turn down rate from a high of
43,000 BTU’s to a low of 23,000 BTU’s.
The valve steps down and lowers
pressure gas as it flows into the burner
orifice.

#3

The orifice is a small opening

specifically designed and machined to
allow a precise gas flow into the burner.

#4

Unique to the Ember Fyre burner,

the combustion air is drawn from
outside the house via the direct
vent flue. This air is preheated
and drawn into the lower
portion of the sealed firebox.

#5

A portion of this air is drawn directly into the mixing tube.

#6

The mixing tube combines the gas from the orifice with combustion air and

directs this mixture to the burner.

#7

The fuel/air mixture is fine tuned to your installation with a one time adjustment

using the air shutter control. This control allows the installer to compensate for
variations in altitude, fuel type and line pressure.

#8

This gas/air mixture flows toward the lower burn chamber.

#9

The burn chamber is a hollow area formed between a metal pan and the Ember-

Fyre™ burner (patent pending).

#10

From the sealed chamber the gas/air mixture flows through a unique array of

precise burner ports. There are no visible burner tubes or steel grill components
that one normally sees in a typical gas appliance.

#11

As this mixture ignites and burns, the Ember-Fyre burner heats to a deep red 1200˚

F, realistically mimicking the look of burning wood embers. The hand-carved ceramic
logs have the appearance of partially burned wood. Dancing yellow flames further
enhance the look and feel of a real wood fire.

#12

The optional Modulating Remote Control is also available that allows you to

remotely adjust both the flame height and the speed of the variable speed blower. The
optional blower is required to utilize this feature.

12

2

1

3

4

5

6

7

8

9

11

10

Use these
dimensions when
determining
clearances to
combustibles.

Stove
Dimensions

27 3/8"

33 3/8"

20 3/8"

27 3/8"

13 5/16"

8 1/4"

When the stove is installed directly on carpeting, vinyl or combustible floor other than wood flooring,
the stove must be installed on a metal or wood protection panel, extending the full width and depth
of the stove. (Minimum 27 3/8” wide x 20 3/8” Deep).

10"
4"
4"

20 3/4"
7"
11 3/4"

Clearances To Unprotected Combustible Walls

Stove clearances measured from stove top. Connector clearances measured from flue pipe.

Straight Installation

Corner Installation

Alcove Installation

Floor Protection

J = Minimum Width 47 3/8"
K = Maximum Depth 48"
L = Minimum Height 60"

A = Stove Top to Sidewall
B = Stove Top to Backwall
C = Stove Top to Corner Wall

D = Connector to Sidewall
E = Connector to Backwall
F = Connector to Corner Wall

BACKWALL

SIDEW

ALL

CORNER WALL

CORNER W

ALL

J

K

L

D

A

E B

C

F

Shown with standard Black Door & optional Gold Grill.