Microprocessor problems, Monitor problems, Microprocessor – Lenovo THINKSERVER TS100 6434 User Manual

Page 82: Problems, Monitor

Advertising
background image

Microprocessor

problems

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Symptom

Action

The

server

emits

a

continuous

beep

during

POST,

indicating

that

the

startup

(boot)

microprocessor

is

not

working

correctly.

1.

Make

sure

that

the

microprocessor

is

supported

on

this

server.

2.

(Trained

service

technician

only)

Make

sure

that

the

microprocessor

is

seated

correctly.

3.

Replace

the

following

components

one

at

a

time,

in

the

order

shown,

restarting

the

server

each

time:

a.

(Trained

service

technician

only)

Microprocessor

b.

(Trained

service

technician

only)

System

board

Monitor

problems

Some

Lenovo

monitors

have

their

own

self-tests.

If

you

suspect

a

problem

with

your

monitor,

see

the

information

that

comes

with

the

monitor

for

instructions

for

testing

and

adjusting

the

monitor.

v

Follow

the

suggested

actions

in

the

order

in

which

they

are

listed

in

the

Action

column

until

the

problem

is

solved.

v

See

the

parts

listing

in

the

Hardware

Maintenance

Manual

to

determine

which

components

are

customer

replaceable

units

(CRU)

and

which

components

are

field

replaceable

units

(FRU).

v

If

an

action

step

is

preceded

by

“(Trained

service

technician

only),”

that

step

must

be

performed

only

by

a

trained

service

technician.

Symptom

Action

Testing

the

monitor

1.

Make

sure

that

the

monitor

cables

are

firmly

connected.

2.

Try

using

a

different

monitor

on

the

server,

or

try

using

the

monitor

that

is

being

tested

on

a

different

server.

3.

Run

the

diagnostic

programs.

If

the

monitor

passes

the

diagnostic

programs,

the

problem

might

be

a

video

device

driver.

4.

Reseat

the

Remote

Supervisor

Adapter

II

SlimLine

(if

one

is

installed).

5.

Replace

the

Remote

Supervisor

Adapter

II

SlimLine

(if

one

is

installed).

6.

(Trained

service

technician

only)

Replace

the

system

board.

The

screen

is

blank.

1.

Make

sure

that:

v

The

server

is

turned

on.

If

there

is

no

power

to

the

server,

see

“Power

problems”

on

page

71.

v

The

monitor

cables

are

connected

correctly.

v

The

monitor

is

turned

on

and

the

brightness

and

contrast

controls

are

adjusted

correctly.

v

A

single

beep

sounds

when

the

server

is

turned

on,

indicating

the

successful

completion

of

POST..

2.

Make

sure

that

the

correct

server

is

controlling

the

monitor,

if

applicable.

3.

Make

sure

that

damaged

BIOS

code

is

not

affecting

the

video;

see

“Recovering

from

a

BIOS

update

failure”

in

the

Hardware

Maintenance

Manual

.

4.

See

“Solving

undetermined

problems”

in

the

Hardware

Maintenance

Manual.

68

ThinkServer

TS100

Types

6431,

6432,

6433,

6434:

Installation

Guide