14. Installation

Connecting the cable to the Outdoor unit.

CAUTION: Provide a circuit breaker

between power source and the unit as
shown below.

CAUTION: The power cord connected to the outdoor unit should be complied with the fol-

lowing specifications (Cable type approved by HAR or SAA).

The power connecting cable connected to the indoor and outdoor unit should be com-
plied with the following specifications (Type "B" approved by HAR or SAA).

Air

Conditioner

Main power source

Circuit Breaker
Use a circuit breaker
or time delay fuse.

GN/YL

20mm

18k

24k

30k

40k

2.5

2.5

3.5

5.5

Cable Type

H05RN-F H05RN-F H05RN-F H05RN-F

NORMAL CROSS

SECTIONAL AREA

Grade

(mm

2

)

NORMAL
CROSS-SECTIONAL
AREA 0.75mm

2

H05VV-F

ø

7.5mm

GN/YL

20mm

1. Remove the control cover from the unit by loosening

the screw.
Connect the wires to the terminals on the control
board individually as the following.

2. Secure the cable onto the control board with the

holder (clamper).

3. Refix the control cover to the original position with

the screw.

4. Use a recongnized circuit breaker between the

power source and the unit. A disconnection device
to adequately disconnect all supply lines must be fit-
ted.

Circuit

Breaker

(A)

Grade (Btu/h)

14k

18k/21k

30k

15

20

30

Power cord

Connecting

cable

Cover control

Terminal block

Outdoor unit

Over 5mm

Holder for

power supply

cord

Loosen terminal screw

Terminal block