TROUBLESHOOTING GUIDE

MODEL 1621-000 EA 230/400 VAC 50 HZ 3 PHASE

MODEL 1628-000 A 220/380 VAC 50 HZ 3 PHASE

MODEL 1629-000 A 240/415 VAC 50 HZ 3 PHASE

NOTE: When checking components on left side of unit, be sure to check for proper connections in power

connector, (marked P. C. on schematic diagram) located inside motor cover.

SYMPTOM

POSSIBLE CAUSE

EVALUATION

Incoming power supply

Check breakers/ reset if required call Power company

if needed.

Fuse, 10 A., main fan

Check, replace if necessary.

Fuse holder

Check, replace if necessary.

Filter, Power

Check for supply voltage to filter. If there is no voltage,

trace wiring back to fuse holder. If there is power in to

the filter, but no power out, replace the filter.

Oven fan switch

Check continuity between switch terminals.

20 minute time delay relay

Check for supply voltage to terminal #1 and #3, if

there is no voltage, trace wiring back to the power

filter. If voltage is present, check for supply voltage at

terminals #3 to #6, if no voltage is present, trace

wiring back to on/off switch. If there is voltage at #3

and #6, check for voltage at terminals #1 and #2, of

there is no voltage at Terminals #1 and #2, replace

the 20 minute time delay relay.

Relay, main fan motors

Check for power to coil of motor relay. If no voltage is

present, trace wiring back to 20 minute time delay

relay. Check for supply voltage to the contact of the

relay. If no voltage is present, trace wiring back to

power filter. If voltage is present, at the relay coil,

check to insure the contacts are closing. Replace

relay as needed.

Hi-limit thermostat(s), control

box

Terminals are normally closed, if open, reset

thermostat and test oven for proper operation. If it will

not reset, replace thermostat.

Capacitor(s)

Check for opens, shorts, or grounds.

Oven fan will not

run

Motor(s), main fan

Check for opens, shorts, or grounds.

No main fan cool

down

20 minute time delay relay

Check for supply voltage at terminals #1 and #2 while

is “ON”. Turn “OFF” the main fan switch, supply

voltage should continue to be present for 20 minutes.

If voltage is not present for 20 minutes, replace 20

minute time delay relay.

Fan switch

(SEE OVEN FAN WILL NOT RUN.)

Hi-limit thermostat(s)

Terminals are normally closed, if open, reset

thermostat and test oven for proper operation. If it will

not reset, replace thermostat.

Relay, main fan motors

Check for power to coil of oven fan relay. If no voltage

is present, trace wiring back to hi-limit thermostat.

Check for supply voltage to the contact of the relay. If

no voltage is present, trace wiring back to fuse holder.

If voltage is present, at the relay coil, check to insure

the contacts are closing. Replace relay as needed.

No control box

cooling

Cooling fan(s)

Supply voltage should now be at these motors. If

voltage is present, check motor for open, shorts, or

grounds. WITH POWER OFF: check for locked rotor.

No automatic

control box cooling

Incoming power supply

Check circuit breakers, reset if needed. Call power

company if needed.

Advertising