CONNECTION OF LINCOLN ELECTRIC
WIRE FEEDERS

Shut off welder before making any electrical connections.

-------------------------------------------------------------------------------------

CONNECTION OF LN-7, LN-8 OR LN-742 TO THE
AIR VANTAGE® 500

• Shut the welder off.

• Connect the LN-7, LN-8 OR LN-742 per instructions on the

appropriate connection diagram in the DIAGRAMS section.

• Set the “WIRE FEEDER VOLTMETER” switch to either “+” or “-

” as required by the electrode being used.

• Set the “SELECTOR” switch to the “CV-WIRE” position.

• Adjust the “ARC CONTROL” knob to desired Crispness. SOFT

for MIG and CRISP for INNERSHIELD.

• Set the “WELDING TERMINALS” switch to the “REMOTELY

CONTROLLED” position.

• Set the “IDLE” switch to the “HIGH” position.

CONNECTION OF LN-15 TO THE AIR VANTAGE®
500

These connections instructions apply to both the LN-15 Across-
The-Arc and Control Cable models. The LN-15 has an internal
contactor and the electrode is not energized until the gun trigger
is closed. When the gun trigger is closed the wire will begin to
feed and the welding process is started.

• Shut the welder off.

• For electrode Positive, connect the electrode cable to the "+"

terminal of the welder and work cable to the "-" terminal of the
welder. For electrode Negative, connect the electrode cable "-"
terminal of the welder and work cable to the "+" terminal of the
welder.

Across The-Arc Model:

Attach the single lead from the front of the LN-15 to work
using the spring clip at the end of the lead. This is a control
lead to supply current to the wire feeder motor; it does not
carry welding current.

Control Cable Model:

Connect Control Cable between Engine Welder and Feeder.

• Set the MODE switch to the "CV-WIRE " position.

Across The-Arc Model:

Set the "WELD TERMINALS" switch to "WELD TERMINALS
ON"

Control Cable Model:

Set the "WELD TERMINALS" switch to "REMOTELY
CONTROLLED"

• Set the "WIRE FEEDER VOLTMETER" switch to either "+" or

"-" as required by the electrode polarity being used.

• Set the "ARC CONTROL" knob to "0" initially and adjust to suit.

• Set the "IDLE" switch to the "AUTO IDLE" position

A-8

INSTALLATION

A-8

AIR VANTAGE® 500 CUMMINS