Installation, Technical specifications – under- water cooler – Lincoln Electric IM723-A User Manual

Page 8

Advertising
background image

A-1

INSTALLATION

UNDER-COOLER CART

A-1

TECHNICAL SPECIFICATIONS – UNDER- WATER COOLER

Model / Make

Under-Cooler Cart K1828-1

Input

100-120 VAC 50/60 Hz 1 Phase

Rated Current Draw

60 Hz (2.8-3.5 Amps)

50 Hz (3.5-5.3 Amps)

Operating Pressure

60 psig (413 kPa) (4.1 bar)

Pump Hydraulic
Rating No Flow

Discharge Pressure (gage)
(Relief Valve Setting)

60 PSIG (414 kPa) (4.14 bar) Max.

No Pressure

Flow Rate

1.66 gal/min (6.28 liter/min) Max.

Pump Hydraulic Rating
(Typical Operation)

Discharge Pressure (gage)

53-57 PSIG (365-393 kPa)

Flow Rate

.45-.60 gal/min (1.7-2.3 liter/min)

Reservoir Capacity

2.0 Gallons (7.6 Liters)

For Use Above Freezing: Clean tap, distilled, or de-ionized water

For Use Below Freezing: 50% water and 50% pure ethylene glycol mixture.

Recommended Coolant

DO NOT USE: Automotive anti-freeze that contains rust inhibitors or leak
stoppers. These coolants will damage the pump and block the small internal
passageways of the heat exchanger, affecting cooling performance. To

acquire the proper coolant contact a local welding distributor.

DO NOT USE: Pre-packaged welding industry coolants. These coolants may
contain oil-based substances, which attack the plastic components of the
cooler. Once added to the cooler, these substances are virtually impossible to
purge from the water lines and heat exchanger.

Weight

Shipping

252 lbs. (114 kg)

Reservoir Full (Water)

267 lbs. (121 kg)

Dimensions

Length

41 in (1041 mm)

Width

27 in (686 mm)

Height (Top Face)

21 in ( 533mm )

Height (TIG Interface)

19 in (483 mm)