A-3

INSTALLATION

VANTAGE® 400 (AU)

A-3

SAFETY PRECAUTIONS

Only qualified personnel should install,
use, or service this equipment.

Do not attempt to use this equipment until you
have thoroughly read the engine manufacturer’s
manual supplied with your welder. It includes
important safety precautions, detailed engine
starting, operating and maintenance instructions,
and parts lists.

------------------------------------------------------------------------

ELECTRIC SHOCK can kill.
• Do not touch electrically live parts or

electrode with skin or wet clothing.

• Insulate yourself from work and

ground

• Always wear dry insulating gloves.

------------------------------------------------------------------------

ENGINE EXHAUST can kill.
• Use in open, well ventilated areas or

vent exhaust outside.

------------------------------------------------------------------------

MOVING PARTS can injure.
• Do not operate with doors open or

guards off.

• Stop engine before servicing.
• Keep away from moving parts.

------------------------------------------------------------------------

See additional warning information at

front of this operator’s manual.

WARNING

VRD (VOLTAGE REDUCTION DEVICE)

The VRD feature provides additional safety in the CC-Stick
mode especially in an environment with a higher risk of
electric shock such as wet areas and hot humid sweaty
conditions.

The VRD reduces the OCV (Open Circuit Voltage) at the
welding output terminals while not welding to less than 13V
DC when the resistance of the output circuit is above 200

(ohms).

The VRD requires that the welding cable connections be
kept in good electrical condition because poor connections
will contribute to poor starting. Having good electrical con-
nections also limits the possibility of other safety issues
such as heat-generated damage, burns and fires.

The machine is shipped with the VRD switch in the “ON”
position. To turn it “On” or “Off”:

• Turn the engine “Off”.
• Disconnect the negative battery cable.
• Lower the control panel by removing 4 front

panel screws. (See Figure A.1)

• Place the VRD switch in the “On or “Off” position.

(See Figure A.1)

With the VRD switch in the “On” position, the VRD lights
are enabled.

LOCATION AND VENTILATION

The welder should be located to provide an unrestrict-
ed flow of clean, cool air to the cooling air inlets and to
avoid restricting the cooling air outlets. Also, locate
the welder so that the engine exhaust fumes are prop-
erly vented to an outside area.

STACKING
VANTAGE® 400 (AU) machines cannot be stacked.

ANGLE OF OPERATION
Engines are designed to run in the level condition
which is where the optimum performance is achieved.
The maximum angle of continuous operation is 25
degrees in all directions, 35 degrees Intermittent (less
than 10 minutes continuous) in all directions. If the
engine is to be operated at an angle, provisions must
be made for checking and maintaining the oil level at
the normal (FULL) oil capacity in the crankcase.

When operating the welder at an angle, the effective
fuel capacity will be slightly less than the amount
specified.

LIFTING
The VANTAGE® 400 (AU) weighs approximately
1383 lbs. (627kg.) with a full tank of fuel, 1230 lbs.
(559kg.) less fuel. A lift bail is mounted to the machine
and should always be used when lifting the machine.

(VRD)-VOLTAGE REDUCTION DEVICE
SWITCH IS LOCATED IN THIS AREA.

REMOVE 4 FRONT PANEL
SCREWS TO ACCESS
(VRD) SWITCH

FIGURE A.1