Warnings – Lennox Hearth GRANDVIEW GV230 User Manual

Page 22

Advertising
background image

22

NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.

ROOM AIR

BLOWER

SPEED

CONTROL/OFF

TWO POSITION

SWITCH

MANUAL/TEMPERATURE

AUTO-RESET TEMPERATURE

SWITCH N/O

POWER CORD

RED

BLK

RED

YLW

BLK

WHT

GRN

NOTE: SWITCH CONDITIONS

GIVEN AT ROOM TEMPERATURE

N/C = NORMALLY CLOSED

N/O = NORMALLY OPEN

= FEMALE DISCONNECT

= MALE DISCONNECT

= STUD CONNECTION

WARNINGS

The blower must be plugged directly into a properly

grounded three-prong receptacle, 120 VAC, 60 Hz, single

phase. Do not cut or remove the grounding prong from

this plug. Do not route power cord under or in front of

appliance.
Installation must be in accordance with National Elec-

trical Code, ANSI/NFPA 70 - latest edition. In Canada,

the current CSA C22.1 Canadian Electrical Code - latest

edition.
DANGER: Disconnect power before servicing blower.
In the event that you remove the blower for any reason,

make sure a cover plate (available from Lennox Hearth

Products) is installed before using the heater. Excessive

rear wall temperatures will result if the stove is burned

without the cover plate. The cover plate is not necessary

if a blower has never been installed because a knock-out

will be in place to act as the cover.

Figure 28 - Blower Wiring Schematic

Blower Operation Guidelines
While in auto operation mode, the blower will turn off and on based on

The temperature of the stove or fireplace insert. Auto operation ensures

there is sufficient heat build-up to warm the air being moved by the blow-

er before the blower is turned on. Likewise, when the stove cools off, the

blower is turned off to prevent circulating cool air. Depending on the size

and intensity of the fire it may be necessary to adjust the fan speed ac-

cordingly to ensure uninterrupted fan operation. For example a small fire

may require a slower fan speed to keep the heat output by the fan con-

sistent. If the blower is operated in manual mode, it may be necessary to

adjust the blower speed as the fire begins to burn down and the stove is

no longer hot enough to effectively heat the air moved by the blower. If

the air coming from the blower feels cool, one should either decrease the

blower speed or stoke the fire to build up more heat.

NOTE: Turn blower off before opening the door to load the fuel.

BLOWER OPERATION (OPTIONAL KIT)

Figure 29 - Blower Controls

Blower Operation

The blower can be operated in either manual or automatic mode. When

operated automatically, the blower will turn on when the stove is hot,

and turn off when the stove is cool.

MANUAL OPERATION: Flip blower mode switch to the

manual position (up) and adjust blower speed dial to desired setting.

To turn blower off, rotate blower speed dial counter clockwise until it

clicks “off.”

AUTO OPERATION: Flip blower mode switch to auto posi-

tion and turn blower speed dial clockwise until it clicks out of the “off”

position. When the stove warms up (approx. 15-20 Mins), the blower

will automatically turn on (adjust blower speed dial to desired speed

setting). When the stove or insert cools down, the blower will auto-

matically turn off.

Manual / Auto

Rocker Switch

Blower Speed

Control Knob

Advertising