NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Periodically (After the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

Cleaning Firebox Interior

Check Flame Patterns and Flame Height

Checking Vent System

Cleaning Front Glass Enclosure Panel

Homeowner

Homeowner

Homeowner

Homeowner

Carefully remove logs, rockwool and decora-
tive volcanic stone and vermiculite. Vacuum
out interior of the firebox. Clean firebox walls
and log grate. Replace logs, Rockwool and
volcanic stone as detailed in this manual.

Maintenance Task

Accomplishing Person

Procedure

Inspecting/Cleaning Burner, Logs
and Controls

Check Flame Patterns and Flame Height

Inspecting/Cleaning Pilot and Burner

Checking Vent System

Appliance Checkout

Replacing Rockwool Ember Materials

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Qualified Service Technician

Homeowner/Qualified Services Technician

Inspect valve and ensure it is properly operat-
ing. Check piping for leaks. Vacuum the
control compartment, fireplace logs and burner
area.

Refer to

Figures 6 (EDV3530), 7 (EDV4035)

or 8 (EDV4540) on page 7 and verify the
flame pattern and height displayed by the
appliance conforms to the picture. Flames
must not impinge on the logs.

Refer to

Figure 9 (SIT) or Figure 10 (Honeywell)

on page 8. Remove any surface build-up on
pilot and burner assembly. Wipe the pilot nozzles,
ignitor/flame rod and hood. Ensure the pilot
flame engulfs the flame sensor as shown.

Inspect the vent system at the top and at the
base (within the firebox) for signs of blockage
or obstruction. Look for any signs of disloca-
tion of the vent components.

Perform the appropriate appliance checkout
procedure detailed in this manual.

Remove old ember materials and vacuum the
rockwool placement area. Place new rockwool
as described in this document.

Maintenance Schedule

Annually (Before the onset of the Burning Season)

Clean as necessary following the directions
provided in this manual. DO NOT TOUCH OR
ATTEMPT TO CLEAN GLASS WHILE HOT
.

Inspect the vent system at the top and at the
base (within the firebox) for signs of block-
age or obstruction. Look for any signs of
dislocation of the vent components.

Refer to Refer to

Figures 6 (EDV3530), 7

(EDV4035) or 8 (EDV4540) on page 7 and
verify the flame pattern and height displayed
by the appliance conforms to the picture.
Flames must not impinge on the logs.