Troublshooting, Troubleshooting, Sympton possible cause – Lang Manufacturing AGC User Manual

Page 14

Advertising
background image

14

9

.

TROUBLESHOOTING

9.1 Symptoms

What follows is a chart of Symptoms and Possible Causes to aid in diagnosing faults with the Clamshell®.
Refer to the Symptoms column to locate the type of failure then to the Possible Cause for the items to be
checked.
To test for a possible cause, refer to the TEST section and locate the Possible Cause then refer to test to
identify test procedures.

SYMPTON

POSSIBLE CAUSE

Igniter not sparking

• Failed spark module

• Failed tilt switch

• Failed air switch

• Failed motor blower

• Failed transformer

• Failed spark electrode

Spark but no ignition

• Failed spark controller

• Failed gas solenoid valve

• Clamshell® gas valve turned off

• Plugged orifice

Clamshell® turns off after extended use

• Incorrectly adjusted sense electrode

Taking too long to light

• Incorrectly adjusted spark electrode

• Plugged enrichment orifice

• Plugged burner tiles

Hazy blue flame on tile face

• Incorrectly adjusted air shutter

• Leak in air path to burner face

• Incorrectly adjusted gas regulator

Not hot enough

• Incorrectly adjusted gas regulator

• Plugged main burner orifice

• Plugged burner tiles

Clamshell® not turning off

• Failed tilt switch

• Failed gas solenoid valve

Blower runs continuously

• Normal operation