CLU Reports a Problem

The CLU reports information passively—you must determine which functions to
check based on the sound of the VTrak’s audible alarm (see page 261) and any
amber or red LEDs (see page 262).

In this example, let us check disk array status.

1.

Open the CLU.

2.

Highlight Disk Array Management and press Enter.

3.

Observe the status of your disk arrays.

DaId

Alias OpStatus CfgCapacity FreeCapacity

MaxContiguousCap

-------------------------------------------------------------------------------------------
0

DA0

OK

75.44GB

66.06GB

66.06GB

1

DA1

Degraded 189.06GB

179.68GB

179.68GB

2

DA2

OK

73.57GB

64.20GB

64.20GB

At this point, you can highlight the Degraded array and press Enter to see more
information. See below.

Disk Array ID

: 1

Physical Capacity

: 189.06GB

OperationalStatus

: Degraded

MaxContiguousCapacity : 11.18GB

FreeCapacity

: 179.68 GB

ConfigurableCapacity

: 179.68GB

SupportedRAIDLevels: 0 5 10 1E

Disk Array Alias

: DA1

MediaPatrol

: Enabled

PDM : Enabled

Transport
Rebuild
Predictive Data Migration
Transition
Dedicated Spare Drives in the Array
Physical Drives in the Array
Logical Drives in the Array
[Locate Disk Array]

Save Settings

[CTRL-A]

Restore Settings

[CTRL-R]

Return to Previous Menu

From this screen:

Highlight Physical Drives in the Array and press Enter to identify the failed
disk drive