Chapter 4: Management with WebPAM PROe

107

5.

To enable CIM using a HTTPS connection:

Choose the Yes option

Enter a port number in the field provided (5989 is the default)

6.

To enable authentication for your CIM connection(s):

Choose the Yes option

Enter the old password in the field provided (password is the default)

Enter a new password in the field provided

To change your password, the CIM service must be running. See “Manual
Start, Restart, Stop” on page 106.

The default name is cim. You cannot change the name or add users.

7.

Click on the Submit button.

Netsend

VTrak’s Netsend service sends VTrak subsystem events in the form of text
messages to your Host PC and other networked PCs. In order to use Netsend:

Netsend must be running on the VTrak

You must provide the IP address for each recipient PC

The Messenger service must be running on each recipient PC

Manual Start, Restart, Stop

To manually start, restart or stop the Netsend service:

1.

Click on the Subsystem

icon in Tree view.

2.

Click on the Administration Tools

icon.

3.

Click on the Netsend link.

4.

Under Running Status:

If the service is stopped, click the Start button to start the service.

If the service is started, click the Stop button to stop the service. Or click
on the Restart button to restart the service.

Change Start Setting

To change the Netsend Automatic/Manual start setting:

1.

Click on the Subsystem

icon in Tree view.

Note

If your Netsend and Messenger service settings are correct but
the recipient PC does not receive event messages, check the
recipient PC’s Firewall settings. Refer to your OS documentation
for more information.