LAMP INDICATIONS

Green Lit

Charger is plugged into the AC outlet.

Ready to charge.
Green Flashing Quickly

Charging is completed. (Full charge.)
Green Flashing

Battery is approximately 80% charged. (Usable charge.

Li-ion only.)
Green Lit

Now charging.
Orange Lit

Battery pack is cool.

The battery pack is being charged slowly to reduce the load

on the battery. (Li-ion only.)
Orange Flashing

Battery pack is warm. Charging will begin when temperature

of battery pack drops.
If the temperature of the battery pack is –10°C (14°F) or less,

the charging status lamp (orange) will also start flashing.

Charging will begin when the temperature of the battery pack

goes up (Li-ion only).
Charging Status Lamp

Left: green Right: orange will be displayed.
Both Orange and Green Flashing Quickly

Charging is not possible. Clogged with dust or malfunction of

the battery pack.

VII

.

MAINTENANCE

Use only a dry, soft cloth for wiping the unit. Do not use a damp cloth, thinner, ben-

zine, or other volatile solvents for cleaning.

VIII

.

TIGHTENING TORQUE

The power required for tightening a bolt will vary, according to bolt material and size,

as well as the material being bolted. Choose the length of tightening time accordingly.

Reference values are provided below.

(They may vary according to tightening conditions.)

Factors Affecting Tightening Torque

The tightening torque is affected by a wide variety of factors including the follow-

ings. After tightening, always check the torque with a torque wrench.

1) Voltage

When the battery pack becomes nearly discharged, the voltage decreases and the

tightening torque drops.