Surveillance Unit

WU-ZS001E

MAJOR OPERATING CONTROLS & TERMINALS

Top of Unit

1 CN101 Terminal
2 CN102 Terminal
3 CN103 Terminal
4 CN104 Terminal

5 DIP Switches

6 SURVEILLANCE I/F Connector

PREFACE

This Surveillance Unit is intended for installation on the WA-
MA120N/240N Mixing Power Amplifier (sold separately).
Installation of the Surveillance Unit ensures system reliability
and safety by detection of speaker line failures, as well as
audio signal problems and abnormally high temperatures in
the amplifier.
• Detects and notifies speaker line faults (shorts,

disconnections, grounding), amplifier audio signal
problems, and abnormally high amplifier temperatures.

• A built-in interval timer schedules automatic checks for

speaker line failures at a preset interval.

• Non-stop monitoring for amplifier audio signal problems and

abnormally high temperatures, and notifies when
abnormalities are discovered.

• Speaker line failure detection can be executed by Sound

Message Unit scheduler.

• Switch operation allows manual execution of speaker line

check.

• SURVEILLANCE I/F connector supports execution of

speaker line check and acquisition of each fault notification.

• Fault notification from the SURVEILLANCE I/F connector

allows configuration of a system that switches to a backup
amplifier when the power amplifier has a problem.

FEATURES

Speaker Line Check

• Speaker lines can be checked individually for shorts and

disconnections.

• Overall speaker line check for grounding.
• Speaker line check is performed according to the time

interval setting.
Notification about any faults occurred during the time interval
will not be made at once. See the illustration below for
details.

• Check interval can be set to none, 10 minutes, 60 minutes,

or 24 hours. The factory default setting is 24 hours.

• Execution of speaker line failure detection cancelled during

all-zone announcement.
And it will not be resumed automatically when all-zone
announcement ends.

• Indicators on the front panel of the mixing power amplifier

signal malfunction. Notification of the fault is also sent from
the SURVEILLANCE I/F connector at the same time.
Detection of a short in a speaker line causes automatic cut
off of the line's output.

• CHECK/SETTING switch can be used to execute the

speaker line check or to set the line impedance reference

value. The same setting is also possible from the
SURVEILLANCE I/F connector.

• The Surveillance Unit's indicator and the FAULT indicator on

the front of the mixing power amplifier flash to indicate that
speaker line failure detection is in progress and while the line
impedance reference value is being obtained.

• Detection of a short causes the applicable line to be cut.
• The speaker line check will not be performed during all-zone

announcement.
And when there is no all-zone announcement, it will be
performed as scheduled by the time interval setting.

Detection of Amplifier Audio Signal Problems

• Audio output of the amplifier is constantly monitored to

ensure operation is normal.

• Indicators on the front panel of the mixing power amplifier

signal problems. Notification of the problem is also sent from
the SURVEILLANCE I/F connector at the same time.

Detection of Abnormally High Amplifier Temperature

• The amplifier is constantly monitored to ensure normal

temperature increase.

• Indicators on the front panel of the mixing power amplifier

signal abnormalities. Notification of the abnormality is also
sent from the SURVEILLANCE I/F connector at the same
time.

Check

Fault

Next fault detection and notification

Check

(n-1)

(n)

Time

Time interval

DIP Switch

Name

Description

Settings

Factory

Number

Default

1

Fixed settings

Fixed at factory default setting

ON

2

TIMER1

Interval timer setting 1

None/10 minutes/ 24 hours

3

TIMER2

Interval timer setting 2

60minutes/24 hours

4

MASTER/SLAVE

Master/slave setting

MASTER/SLAVE

MASTER

5

POWER ON CHECK

Power on speaker line check setting ON/OFF

ON

6

BUS SYNC ENABLE

Speaker line test sync on/off for

ON/OFF

OFF

multi-amp connection

Pin Number

Signal Name

IN/OUT Signal/Logic

Required Action

1

ZONE1 SHORT

OUT

Active Low Zone 1 speaker line is shorted.

2

ZONE1 OPEN

OUT

Active Low Zone 1 speaker line is disconnected.

3

ZONE2 SHORT

OUT

Active Low Zone 2 speaker line is shorted.

4

ZONE2 OPEN

OUT

Active Low Zone 2 speaker line is disconnected.

5

ZONE3 SHORT

OUT

Active Low Zone 3 speaker line is shorted.

6

ZONE3 OPEN

OUT

Active Low Zone 3 speaker line is disconnected.

7

Reserved

8

Reserved

9

Reserved

10

Reserved

11

GROUND FAULT

OUT

Active Low Some speaker lines are grounded.

12

PA SIGNAL FAULT

OUT

Active Low Power amplifier audio signal is faulty.

13

CHECKING/SETTING

OUT

Active Low During measurement of the speaker line reference

BUSY

impedance or during check of the speaker lines.

14

REFERENCE ERROR

OUT

Active Low The speaker line reference impedance couldn’t

be measured successfully.

15

GND

GND

GND

16

PA TEMP FAULT

OUT

Active Low Power amplifier temperature is faulty.

17

COMM FAULT

OUT

Active Low Serial Communication is faulty.

18

Reserved

19

Reserved

20

Reserved

21

GND

GND

22

CLOCK ADJ CONT

IN

One-shot make Adjust control of Interval clock

23

SP LINE REFERENCE

IN

One-shot make Measurement of the speaker line reference

SETTING ACTIVATION

impedance (Initial setting) starts.

24

SP LINE CHECK

IN

One-shot make Check of the speaker line impedance starts.

ACTIVATION

25

GND

GND

GND